2014-
02
26
Commands
7.5.3
Email function
In the
window, enter the error codes that will prompt the IDENTControl Compact to send
an email. Every response that the IDENTControl Compact sends is allocated a status. The
IDENTControl Compact sends an email when the status and error code of a channel are the
same.
Do not enter an error code for channels that are not connected to a read/write head or are
connected to a trigger sensor. If you intend to enter several error codes, separate them with
commas. Enter a maximum of five error codes per channel.
We recommend the following entries for error codes:
■
6: Hardware error
■
7: Internal device error
Setting the email function
1. Enter the recipient address in the
mail address receiver
box.
2. Enter the email address allocated to the device (sender) in the
mail address sender
box.
The email server may have to recognize the address, depending on the SMTP server.
3. Enter the IP address of the SMTP server in the
IP address smtp server
box.
4. Enter the error codes for channel 1 or channel 2 in the
mail triggered by error codes
boxes. Separate the digits with commas.
5. Enter the subject in the
Subject
box.
6. Enter any text that you wish to include in the email such as a location or series information in
the
Additional email text
box. The device adds the channel, the type designation of the
read/write head, and the cause of the error that has occurred to this text.
Note!
Duplex mode
We recommend the setting
auto detect
for duplex mode. If you do not select
auto detect
,
make sure that the same duplex mode is preset for the device communication partner (e.g. the
switch).
Note!
Your network will require an SMTP server for you to use the email function.
room 7, line 4, identification system 45