2597
78 2013-
02
58
Software description PF_Ident
Description of menu entries
Instructions on Write fixcode function
Write fixcode
Write a fixcode to a data carrier as follows:
1. Select
Read/Write > Write fixcode > Fix type
.
2. Press the CLEAR input key (
) to delete the default value.
3. Depending on whether you wish to set a variable or rewritable fixcode, enter
the relevant value using the input keys. See see "Fix type" on page 55
4. Press the left softkey (
) to confirm your entry.
5. Select
Data
.
6. Enter the relevant data in the correct syntax for the data format selected using
the input keys. The length of the fixcode is 5 bytes.
7. Press the left softkey (
) to confirm the entry.
If the character entered does not correspond with the syntax of the data
format, a fault indication is issued and the value is not accepted.
8. Position the read/write head on the Handheld directly beside the data carrier.
9. Press the left softkey (
) to confirm the entry.
If the write process is successful, "OK" appears on the display and the status LED
flashes green. If you have activated the buzzer and the vibration alarm in the
Settings
menu, an acoustic signal sounds and the Handheld vibrates. If the
transfer was unsuccessful, the status LED briefly flashes red and a fault indication
is issued. See see chapter 8
Button
Description
Left
The command from the higher level menu is assigned to the left function
button (
).
Right
The command from the higher level menu is assigned to the right
function button (
).
Handle
The command from the higher level menu is assigned to the function
button on the handle.
Note!
Observe the input format
Data bytes in hexadecimal data format must always contain 2 characters and data
bytes in decimal data format must contain 3 characters.