2597
78 2013-
02
108
Commands
10.4
IQ* Read/Write Heads
Operating frequency: 13.56 MHz.
10.4.1
Command reference
Single Read Words (SR)
Only one attempt is made to read <WordNum> data blocks from block address
<WordAddr>.
Single Write Words (SW)
Only one attempt is made to write <WordNum> data blocks from block address
<WordAddr>.
Single Read Fixcode (SF)
Only one attempt is made to read fixcode. The specified length of the fixcode
depends on the data carrier type.
4
falscher Befehl
command error
5
kein Transponder
no tag
6
Hardwarefehler
hardware error
7
Softwarefehler
software error
8
Service-Schnittstelle
service interface
9
unbekannter Fehler
unknown error
Status
German display text
English display text
Command
Description
SR
Read data
SW
Write data
SF
Read fixcode
S#
Format data carrier
GS
Read data carrier type
CT
Set data carrier type
Command:
SR
<WordAddr><WordNum>
Response:
<Status><Data>
Command:
SW
<WordAddr><WordNum><Data>
Response:
<Status>
Command:
SF
Response:
<Status><Data>