Operation and communication
5.3
Operation in case of repair
If repairs are required, the
Code Tape Generator
at www.pepperl-fuchs.com can be used as a
Enter the start value in meters and the code tape length of the section to be replaced in meters.
This produces a printable PDF file containing the required segment of the code tape.
The printout must be used only as an emergency solution. The durability of the paper strip is
extremely limited depending on the application!
5.4
Electrical switching output
The read head has two configurable switching outputs. The default setting is stored in the data
sheet.
If the respective switching output is set to "snyc-out", a synchronization pulse is provided at the
switching output. The pulse is synchronized with the image acquisition. The control signal of
the image acquisition (shutter time/flashduration) is provided latency-free at the output and
extended to 1 ms pulse duration.
With the help of this synchronization pulse, the exact temporal assignment of the position data
to the recording time can be realized.
1ms
Sync
Illumination
Shutter time/Flashdurtaion
Cycle time
Illumination