background image

(EFM1)

Evolve

 

LED Flood Light

BEFORE YOU BEGIN

Read these instructions completely and carefully.
Save these instructions for future use.

Risk of electrical shock. Disconnect power before servicing 

or installing product.

Installation Guide

GEH-6066

Risk of injury. Wear safety glasses and gloves during 

 installation and servicing.

Risk of injury or damage. Unit will fall if not installed 

 properly.  Follow installation instructions.

Risk of fire. Use supply wire specified on nameplate.

This device complies with Part 15 of the FCC Rules. Operation is 

subject to the  following two conditions:  (1) This device may not cause 

harmful  interference, and (2) this device must accept any interference 

received,  including interference that may cause undesired operation.  

This Class [A] Lighting Equipment complies with Canadian standards

ICES-005[A]/NMB-005[A].

Note: This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 

These limits are  designed to provide reasonable protection against 

harmful  interference when the equipment is operated in a  commercial 

 environment. This equipment  generates, uses, and can radiate  radio 

frequency energy and, if not installed and used in  accordance with 

the instruction manual, may cause harmful interference to radio 

 communications. Operation of this equipment in a residential area 

is likely to cause harmful  interference in which case the user will be 

required to correct the  interference at his own expense.

•   This luminaire is designed for outdoor lighting   
  applications, and should not be used indoors.

•   Best results will be obtained if installed and   
  maintained according to this simplified guide.

•   This flood light is provided with trunnion, pipe, or wall
 mountings.

SPECIFICATIONS

GENERAL

•  Weight: 25 lbs. (11.34 kg)
•  Effective Projected Area (EPA):
    - 90° aim (vertical glass) 1.96 sq. ft.
    - 45° aim 1.22 sq. ft.
    - Side profile (all aims) 0.73 sq. ft.
    - 0° (face down) aim 0.79 sq. ft.
•   Ingress Protection (IP) rating:
    - Optical: IP66
    - Electrical Enclosure: UL Wet Location
•   Ambient temperature: -40°C (-40°F) to 50°C (140°F)

WARNING

WARNING

WARNING

CAUTION

Summary of Contents for Evolve EFM1

Page 1: ...to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment i...

Page 2: ... Do not mount unit upside down Tighten set screws to 25 30 ft lbs 34 41 N m of torque Tighten Knuckle Bolt to 15 to 20 ft lbs torque after aiming 2b Wall Mount Mount to vertical surface using four 0 43 inch clearance holes spaced 4 37 H x 2 87 V inches with customer supplied fasteners anchors Seal wall mount flange to the mounting surface with silicone caulk or equivalent Tighten Knuckle Bolt to 1...

Page 3: ...n the groove Tighten trunnion or knuckle bolts per instructions in Section 2 FIGURE 4 Aiming Sight Front of sight Target Rear of sight FIGURE 5 Maximum Aiming Range with PE PE Units Regardless of mounting type units with a photoelectric receptacle cannot be aimed more than 60 degrees above horizontal 60 MAX 3 WIRING Note Make all electrical connections in accordance with National Electrical Code a...

Page 4: ...roblems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to Current powered by GE All trademarks are the property of their respective owners Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions Current powered by GE is a business of the General Electric Company 2...

Page 5: ...a Section 15 des règlements de la FCC Ces limites sont établies pour assurer une protection raisonnable contre les interférences nuisibles lorsque l équipement est mis en service dans un environnement commercial Cet équipement émet utilise et peut radier une énergie de radio fréquence et s il n est pas installé et utilisé suivant les instructions du manuel pourrait causer des interférences nuisibl...

Page 6: ...r tourillon Montez sur une surface plate en utilisant un boulon de po 19 mm fournis par le client au travers du trou de montage situé au bas du tourillon Après orientation serrez les 2 goujons latéraux à un couple de 15 à 20 ft lbs 2 04 à 2 72 daNm Au besoin le tourillon peut être bloqué en rotation en utilisant des boulons fournis par le client au travers des trous de montage supplémentaires situ...

Page 7: ...E 4 Mire d orientation Avant de la mire Cible Arrière de la mire FIGURE 5 Distance maximum de visée avec boîtier Photoélectrique Appareils avec cellule photoélectrique Indépendamment du type de montage les appareils avec cellule photoélectrique ne peuvent pas être orientés plus que 60 au dessus de l horizontale 60 MAX 3 CÂBLAGE Remarque Procédez à tous les raccordements électriques en respectant l...

Page 8: ...r se présente qui n est pas couvert suffisamment pour votre cas soumettez le à Current powered by GE Toutes les marques déposées sont la propriété de leurs propriétaires respectifs Les informations fournies sont sujettes à modification sans préavis Toutes les valeurs données sont théoriques ou typiques lorsque mesurées sous conditions de laboratoire Current powered by GE est une entreprise de Gene...

Page 9: ...mento FCC Estos límites están diseñados para proporcionar protección razonable contra interferencias perjudiciales al operar el equipo en un entorno comercial Este equipo genera utiliza y puede irradiar energía de radiofrecuencia y si no se instala y utiliza de acuerdo con el manual de instrucciones puede causar interferencias perjudiciales a las comunicaciones por radio Operar este equipo en una ...

Page 10: ...ón desde 20 4 a 27 1 metros Newton 15 a 20 libras de pie después de apuntar 2c Montaje de muñón Monte en una superficie plana con un perno suministrado para el cliente de 1 91 cm 0 75 pulgadas a través del agujero de paso en la parte inferior de del muñón Apriete los dos 2 pernos de muñón a un par de torsión de 20 4 a 27 1 metros Newton 15 a 20 libras de pie después de apuntar Si lo desea puede fi...

Page 11: ...e posterior de la vista FIGURA 5 Alcance máximo de puntería con PE Unidades PE Independientemente del tipo de montaje las unidades con un receptáculo fotoeléctrico no pueden tener una puntería de más de 60 grados sobre horizontal MÁXIMO DE 60 3 CABLEADO Nota Haga todas las conexiones eléctricas de acuerdo con el Código Eléctrico Nacional y cualquier requisitos de códigos locales Nota Antes de la i...

Page 12: ...e no estén cubiertos suficientemente para los propósitos del comprador debe remitirse el asunto a Current powered by GE Todas las marcas registradas son propiedad de sus respectivos propietarios La Información proporcionada está sujeta a cambios sin previo aviso Todos los valores son de diseño o valores típicos cuando se miden bajo condiciones de laboratorio Current powered by GE es una empresa de...

Reviews: