MOUNTING
2
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 30 ft-lbs of torque on set screws
or 20 ft-lbs of torque on knuckle bolt.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 20 ft-lbs of torque on knuckle bolt.
WARNING
Risk of injury or damage. Unit will fall if not installed
properly. Do NOT exceed 20 ft-lbs of torque on trunnion bolt.
• Inspect luminaire to confirm no damage has occurred
during transit.
• To avoid damage, do not impact or stack luminaire
after removal from packaging.
UNPACKING/HANDLING
1
Clearance hole for Customer
Supplied 3/4” Bolt
2a. Pipe Mount:
Mount on vertical 1-7/8 to 2-3/8-inch
O.D. or 2-3/8 to 3-inch O.D. pipes.
• Pipe must point upward such that gravity acts to hold
luminaire on pipe end.
• Do not mount unit upside down.
• Tighten set screws to 25-30 ft-lbs (34-41 N-m) of torque.
• Tighten Knuckle Bolt to 15 to 20 ft-lbs torque after aiming.
2b. Wall Mount:
Mount to vertical surface using four
0.43-inch clearance holes spaced 4.37(H) x 2.87(V) inches
with customer supplied fasteners/anchors.
• Seal wall mount flange to the mounting surface
with silicone caulk or equivalent.
• Tighten Knuckle Bolt to 15 to 20 ft-lbs torque after aiming.
2c. Trunnion Mount:
Mount on a flat surface using a
customer supplied 3/4-inch bolt through the clearnace
hole provided in the trunion bottom.
• Tighten two (2) side Trunion Bolts to 15 to 20 ft-lbs
torque after aiming.
• If desired, trunion can be secured against rotation
by using customer supplied fastner(s) through
additional clearance holes in the trunion bottom.
Wiring Cover
4.375 in.
4 Holes
.430 in.
2.875 in.
FIGURE 2. Wall Mount
FIGURE 3. Trunnion Mount
Set Screws
Wiring Cover
Knuckle Bolt
Door Hinge
Knuckle Bolt
Trunnion Bolt
Top Closure Screw