5
6. Battery indicator of the Ident-Ex
Description of the LED status of the battery indicator (running on battery)
LED
Battery level
The green LED illuminates permanently
Ident-Ex battery status by 100-60%
The yellow LED illuminates permanently Ident-Ex battery status by 59-30%
The red LED illuminates permanently
Ident-Ex battery status by 29-6%
The red LED blinks
Ident-Ex battery status by 5-0%
Description of the LED status of the battery indicator (while charging)
LED
Battery level
The green LED illuminates permanently
Ident-Ex is fully charged; battery status by 100%
The red and yellow LEDs illuminate
permanently and the green LED blinks
Charging process of Ident-Ex by 99-60%
The red LED illuminates permanently
and the yellow LED blinks
Charging process of Ident-Ex by 59-30%
The red LED blinks
Charging process of Ident-Ex by 29-0%
7. Description of Buttons and LEDs
SPP
Button
Bluetooth
LED
Trigger
Button
Battery
indicator
Power
Button
Power
LED
Scan
LED
SPP
LED
There is only one button on the bottom side of the Ident-Ex. The main trigger.
8. Switching Ident-Ex On and Off with Power Button
To turn on the Ident-Ex, you have to keep the Power Button pressed for 3
seconds. Please note that the Ident-Ex can only be turned off, if the device is in
battery operation.
9. Turning off Ident-Ex through time setting
The Ident-Ex has a setting which allows the device to automatically turn off after
a defined timer period (see “Switch off time” setting in Software Manual DOCT-
7016).
If no Bluetooth connection could be found, the predefined time to automatically
turn the device off will start. If a scan with Trigger or Main Trigger Button will be
started in this time, the predefined time will be resetted and starts again. As long
as the device doesn’t get connected via Bluetooth or a scan will be made during
the predefined time, it will automatically turn off. Again, the Ident-Ex can only be
turned off if it is in battery operation. Turning off the Ident- Ex 01 through time
setting can be disabled by setting the Switch off time = 0.
10. Restart the Ident-Ex
During the charging process, the Ident-Ex 01 will be automatically switched on.
It is not possible to switch off the Ident-Ex 01 during the charging process. To
restart the Ident-Ex 01 during the charging process, press the Power Button for
approx. 10 seconds until the Power LED goes out. Release the Power Button and
the Ident-Ex 01 will start again.
11. Hardware reset
Press the Power Button for approx. 10 seconds and the Ident-Ex 01 is doing a
hardware reset.
12. Settings of the Ident-Ex
The Ident-Ex 01 can be adjusted with the “eSETUP Ident-Ex” App. This App can
be downloaded from the ecom App Library https://www.ecom-ex.com/nc/apps/ .
13. Reset settings
The firmware of the Ident-Ex allows to reset the settings to the factory settings.
Therefore, the buttons Main Trigger, Trigger and SPP have to be pressed simul-
taneously for 2 seconds while starting the Ident-Ex.