18
3.INSTALLATION
Step 3:
Replace the handling bar downward to fasten the CPU to the
socket.
Warning : It is strongly recommended that a heatsink and CPU cooling fan be used to
prevent the CPU from overheating. Applying a thermal of jelly between the
CPU and the heatsink/fan will further cool the CPU.
3.2.2
Set CPU Frequency/Voltage/Speed
For different CPU speeds, you have to configure the jumper settings for your CPU.
Please refer to the following figure and tables to carefully finish it.
CPU Host Frequency
JP2 JP3 JP4
JP5 JP6 JP7 JP8
CPU Ratio
JP11 JP12 JP13 JP14 JP15
CPU Voltage
Now follow the below steps to configure your CPU settings.
Step 1:
Setting CPU Host Frequency (JP5, JP6, JP7, JP8)
Before setting CPU Host Frequency, one thing must be strongly concerned that the 100
MHz CPU Host Frequency only supports the DIMMs with PC/100-compliant. Since
most systems will not even boot if non-compliant modules are used because of the
strict timing issues involved under this speed, please be well learned that your CPU
speed and DIMM module speed indeed match for each other.
Step 3: Fasten the CPU to socket.