28
Installation and User’s Guide
OPERATOR SETUP MENU SCREENS
To access this menu,
press the
Up
and
Down
arrows simultaneously. While in the Operator Setup Menu
screen, if no activity is detected after 15 seconds, the main screen is displayed. To get back into the Setup
menu you must press the
Up
and
Down
arrows simultaneously again.
1.
Language Selection
– Displays the language selected. Select either English or Spanish using the UP and
DOWN arrows.
2.
Software Revision
– Displays the software revision level loaded on the control board.
3.
Pump Start Time
– This displays the period at which the heat pump will close the AutoSet contactor to
start the filter pump. Adjustable from 1 to 4 hours using the UP and DOWN arrows.
4.
Intell Address
– IntelliTouch
®
RS-485 Communications Address which must match the address used in
the IntelliTouch
®
or EasyTouch
®
automation controller being communicated with. Adjustable from 1 to 16
using the UP and DOWN arrows.
5.
Temperature Scale
– Determines if the water temperature actual reading and set point is displayed in
degrees Fahrenheit or Celsius. Adjusted between Fahrenheit and Celsius using the UP and DOWN arrows.
6.
Temp Offset
– Adjusts the measured water temperature up or down to allow the operator to match the
heat pump measured temperature to a remote temperature monitoring device. The offset can be varied
from -2 to +2 using the UP and DOWN arrows.
7.
Defrost Screen
– Allows to Enable/Disable defrost cycle.
TEMP OFFSET
OFFSET = -2 TO +2
SOFTWARE VERSION
REV. __
PUMP START TIME
TIME = 1 - 4 HRS
INTELL ADDRESS
ADDRESS = 1 - 16
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
LANGUAGE / IDIOMA
SELECTED - ENGLISH
DEFROST
ENABLE / DISABLE