Installation and User’s Guide
AUTO MODE
POOL/SPA
6.
Serial Remote On/Off Screen
– Allows the operator to turn the Serial Remote mode On and Off. In
Serial Remote mode, the heat pump is started and stopped with serial communication commands from
the automation controller via the RS-485 link. The local Pool and Spa temperature set points are not
active when operation is in this Serial Remote mode.
7.
AutoSet On/Off Screen
–
This screen is only shown if the AutoSet mode is enabled during factory
setup
. Allows the operator to turn the AutoSet mode On and Off. AutoSet mode periodically energizes a
filter pump contactor to start a remote filter pump which allows the heat pump to heat or cool the water as
necessary.
8.
Time Delay Screen
– If the heat pump is waiting on any of the restart, pump start or sensing water
temperature delays this screen shows how much delay time is left.
9.
Alarm Screen
– If an alarm condition is present it will be displayed on this screen. If no alarms are present
the screen will display ALARM STATUS NONE. The control board has the ability to store a 30 Alarm
history of previous alarms that have occurred. At the alarm status screen, press the DOWN arrow. The
first alarm will be the most recent alarm that has occurred. Successive presses (up to 30) of the DOWN
arrow will display the alarm history in the order of occurrence. The operator can scroll back up using the UP
button. There is an option to erase the history.
First and second press sequence of the DOWN arrow.
10.
Auto Mode Screen
– Displays whether the heat pump is in Heat only, Cool only or Auto mode. It
also displays whether the Pool or Spa set point is active. The active set point can be switched between
Pool and Spa by using the UP and DOWN arrows.
RESTART / PUMP START /
SENSING WATER TEMP
DELAYS
ALARM STATUS
NONE
LATEST ALARM
LOW WATER FLOW
ALARM PRIOR #1
HIGH REFRIG
FIRST PRESS
SECOND PRESS
AUTOSET
OVERRIDE IS ON/OFF
SERIAL REMOTE
ON/OFF