background image

6

QUAD D.E.

®

 Cartridge Style D.E. Filter Installation and User’s Guide

 

Coating the Filter Elements with Diatomaceous Earth (D.E.)

The following information should be read carefully since it outlines the proper manner of care and operation for your 
filter system. You can expect maximum efficiency and life from your filtration system by following these instructions 

and taking the necessary preventative care.

When Using Slide Valve:

1.  Twist to unlock plunger, then raise the handle as far as it will go. Turn handle clockwise to lock lower pin in 

underside of cap.

When Using Multi-port Valve:

1.  Position valve to FILTER OR VACUUM TO POOL setting. This is your normal flow from the pump through the 

filter to the pool. Open the High Flow™ Manual Air Relief Valve on the filter. 

2.  Prepare recommended amount of diatomaceous earth by mixing it with water in a bucket until it is the 

consistency of milk; see page 5, 

Preparing Diatomite

.

3.  On initial start-up the pump must be primed by filling the hair and lint strainer pot with water. You may have to 

do this several times. 

4.  Follow the steps outlined 

on page 5

System Restart Instructions

 for system start-up. 

5.  Introduce the slurry of diatomite from the bucket directly into the top of the skimmer. With the pump running 

and the pool skimmer valve open, pour the mixture directly into the skimmer. The slurry will be drawn into the 
filter.

6.  Your filter is now operational. Note the original starting pressure on the gauge and record it in 

Table 3

.

Note: 

When using a variable speed pump the “Original Starting Pressure” will be dependent on the  pump speed 

(RPM). When recording the original operating pressure, also record the “Original Pump RPM” in 

Table 3

.

7.  Clean your filter when pressure reads between 10 to 12 psi 

higher than the original starting pressure. Your filter pressure 
reading will increase as it removes dirt from your pool. 
However, this build-up of pressure will vary due to different 
bathing loads, temperature, weather conditions, etc.

Note:

 

Pressure build-up varies due to different bathing loads, 

temperature, environmental conditions, etc.  

 Note:

 If the starting pressure after backwashing the filter 

or cleaning the elements indicates 4 to 5 psi higher than 
the normal starting pressure, the filter elements must be 
cleaned. Refer to page 7, 

Manually Cleaning the Filter

 for 

instructions.

Table 3

ORIGINAL  STARTING  PRESSURE  IS:  ________  psi.       
(pounds per square inch) 
SERVICE THE MEDIA AT:  __________ psi.
ORIGINAL PUMP RPM:  __________ rpm.
(for Variable Speed Pumps Only)

Summary of Contents for QUAD 100

Page 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE QUAD D E CARTRIDGE STYLE D E FILTER...

Page 2: ...bing Operation General Filter Operation Clamp Installation System Restart System Restart Instructions Preparing Diatomite Coating the Filter Elements with D E TABLE OF CONTENTS ii 1 1 1 1 1 3 2 2 3 3...

Page 3: ...t the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to ser...

Page 4: ...uring system start up shut down or servicing of the system filter IMPORTANT WARNING AND SAFETY INSTRUCTIONS QUAD D E Cartridge Style D E Filter Installation and User s Guide General Installation Infor...

Page 5: ...t fiberglass reinforced polypropylene tank for exceptional strength and long life 2 plumbing connections for simple and secure maximum flow Conveniently located 2 drain for easy and efficient clean ou...

Page 6: ...oned filter or valve can create an electrical hazard as well as damage property 7 Remove the plug from the top opening in the filter lid and install the manual air relief valve and pressure gauge befo...

Page 7: ...This filter operates under pressure When clamped properly and operated without air in the water system this filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 ps...

Page 8: ...the nut as instructed above in Step 8 9 Continue on to System Restart Instructions on page 5 Note Check the spring coils at least once a month to ensure proper tension If spring coils do not touch tu...

Page 9: ...the filter System Restart Instructions 1 Open the High Flow Manual Air Relief Valve until it snaps into the full open position this only requires a quarter turn counterclockwise Wait until valve relea...

Page 10: ...Introduce the slurry of diatomite from the bucket directly into the top of the skimmer With the pump running and the pool skimmer valve open pour the mixture directly into the skimmer The slurry will...

Page 11: ...inside and out 9 Lift bottom manifold out of the tank and flush off any debris 10 Direct water spray to wash out the inside of the tank body Water and debris will drain out through the open drain port...

Page 12: ...alve rapidly releases air trapped in the filter 3 Stand clear of the filter tank then start the pump 4 Close the manual air relief valve after a steady stream of water appears 5 When water flows clear...

Page 13: ...lement 6 Reinstall the elements and dispose of the acid solution in accordance with local regulations Failure to remove all oils and cleaning solutions from the filter elements before acid soaking wil...

Page 14: ...nsert a 5 16 drill bit through the valve body to ensure the filter tank s air passage is open 5 Be sure the O rings are in good condition properly positioned and lubricated with a silicone base lubric...

Page 15: ...immediately when a This is a characteristic of diatomite filters the filter starts SHORT FILTER RUNS Until the water initially put into the pool has been a Plaster dust can be responsible for short c...

Page 16: ...E The pressure gauge is an important part of the a Check the operation of your pressure gauge IN GOOD WORKING ORDER filter system It is your primary indicator of how in the following manner the system...

Page 17: ...DGE QUAD 60 7 170059 MANIFOLD ASSY BOTTOM QUAD DE 8 190003 CLAMP RPM FLT 9 39010200 O RING RPM TANK CLAMP 10 195339 RING BACKUP FNS PLS CNC PLS 11 196024S DIVERTER ASSY RETRO KIT 12 354571 O RING 200...

Page 18: ...LITY AFTER CLEANABILITY Recommended Flow Rate Model Filter Area Sq Ft Vertical Clearance Flow Rate GPM Res Turnover Capacity Gallons Res Comm 6 hours 8 hours 12 hours Quad 60 60 62 120 150 43 200 57 6...

Page 19: ...15 QUAD D E Cartridge Style D E Filter Installation and User s Guide NOTES...

Page 20: ...A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Penta...

Reviews: