14
QUAD D.E.
®
Cartridge Style D.E. Filter Installation and User’s Guide
TECHNICAL DATA
QUAD D.E.
®
CARTRIDGE STYLE FILTER
HEAD LOSS COMPARISON
0
1
2
3
4
5
6
7
8
9
10
11
20 30 40 50 60 70 80 90 100 110 120 130 140
FILTER FLOW RATE G.P.M.
FILTER PRESSURE LOSS P.S.I.
BEFORE
CLEANABILITY
AFTER
CLEANABILITY
Recommended Flow Rate
Model #
Filter Area
Sq. Ft.
Vertical*
Clearance
Flow Rate GPM
Res. Turnover Capacity (Gallons)
Res.**
Comm.
6 hours
8 hours
12 hours
Quad 60
60
62”
120
150
43,200
57,600
86,400
Quad 80
80
68”
160
150
57,600
76,800
115,200
Quad 100
100
74”
160
150
57,600
76,800
115,200
Flow Rates
NOTE:
Actual system flow will depend on plumbing size and other system components.
*
Required clearance to remove filter elements.
**
Maximum flow rate.
Head Loss Curves