12
P1063 (10-03-19)
Pentair Pentek
*
Solar Drive DIP Switch Settings
DIP Switch 8 - Single Phase 3-wire:
See Figure 12. Used
for setting up the proper mode for single phase operation,
relevant only when DIP switch 2 is set for single phase
operation.
The default setting is for single phase 3-wire
motors disabled, when DIP switch 8 is
OFF (down). To enable 3-wire single phase motors, DIP switch
8 should be ON (up).
DIP Switch 9 – Flow Switch Dry Well Protection:
See Figure
13. When combined with an optional flow switch, the Pentair
Pentek Solar Drive offers dry well protection by setting
DIP switch 9 ON (up) position. The Flow Switch needs to be
installed in-line with the pipe (ask your dealer for Flow Switch
availability). The principle of operation is simple. As soon as
the pump starts and water starts flowing through the pipe,
the magnetic Flow Switch turns ON, which indicates to the
Pentair Pentek Solar Drive that there is water in the well.
If there is no water, the Flow Switch will indicate a dry well
condition, and the Pentair Pentek Solar Drive will turn the
pump off. There is a time delay from the start of the pump
for the Flow Switch signal to activate, which allows time for
water to flow from deep wells. See DIP Switch 10 for time
delay settings.
DIP Switch 10 – Flow Switch Time Delay:
See Figure 14. Used
to define the time delay for Flow Switch sensing. When DIP
switch 10 is OFF (down) (default) the delay time
is 15 seconds, while if it is ON (up), the delay time is
30 seconds. A 15 second setting is used for more shallow
wells (less than 300ft), while 30 seconds is used for deeper
wells (deeper than 300ft).
1 2 3 4 5 6 7 8 9 10 11 12
1-Phase, 3-Wire Enabled
1-Phase, 3-Wire Disabled
Figure 12: 2 or 3-Wire
Single Phase Option
1 2 3 4 5 6 7 8 9 10 11 12
Dry Well
No Dry Well
Figure 13: Dry Well
Indicator Using
Magnetic Switch
1 2 3 4 5 6 7 8 9 10 11 12
30 Seconds
15 Seconds
Figure 14: Time Delay
Motor HP
Phase
PNR Motor
DIP 6
DIP 7
DIP Switches
6 and 7
0.75
3
P43B0007A3-C
UP
UP
1
3
P43B0010A3-C
UP
DOWN
1.5
3
P43B0015A3-C
DOWN
UP
2
3
P43BOO20A3-C
DOWN
DOWN
0.5
1-3W
P43BOO05A2-01
UP
UP
0.75
1-3W
P43BOO07A2-01
UP
DOWN
1
1-3W
P43BOO10A2-01
DOWN
UP
1.5
1-3W
P43BOO15A2-01
DOWN
DOWN
6 7
6 7
6 7
6 7
6 7
6 7
6 7
6 7
Figure 11: Over-current Protection
Summary of Contents for PENTEK PSD25PB
Page 19: ...19 P1063 10 03 19 PAGE LEFT BLANK INTENTIONALLY...
Page 21: ...pentair com P1063 10 03 19 MANUAL DE INSTALACI N Y OPERACI N SOLAR DRIVE PSD25PB PENTEK...
Page 39: ...39 P1063 10 03 19 ESTA P GINA SE DEJ EN BLANCO INTENCIONALMENTE...
Page 59: ...59 P1063 10 03 19 PAGE LAISS E VIDE INTENTIONNELLEMENT...