Installer manual Fleck 9000 SXT - Maintenance
94 / 118
Ref. MKT-IM-020 / C - 21.11.2019
9.4.11
Valve on tank assembly
1. Lubricate the seals with approved silicone grease.
2. Spin the valve (
1
) onto the tank (
2
), ensuring the threads are not cross-threaded.
3. Rotate the valve (
1
) clockwise and freely, without using force until it comes to a stop.
Info
This stop position is considered point zero.
4. Rotate the valve (
1
) clockwise from point zero to between ¼ turn and ½ turn.
Caution - material
Risk of damage due to excessive force !
Do NOT exceed 27 Nm of torque when installing the valve. Exceeding this limit may
damage the threads and cause failure.
Point 0
½ turn
Point 0
¼ turn
Point 0
½ turn
Point 0
¼ turn