Installer manual Fleck 9000 SXT - Programming
Ref. MKT-IM-020 / C - 21.11.2019
53 / 118
Parameter
Options
Definition
Note
FM
Flow meter type
P0.7
¾" paddle wheel -
t0.7
¾" turbine
-
P1.0
1" paddle wheel
-
t1.0
1" turbine
-
P1.5
1½" paddle wheel -
t1.5
1½" turbine
-
P2.0
2" paddle wheel
-
Gen
Generic or
non-Fleck
-
K
Meter pulse
0.1 to 999.9
Litre
Only displayed for generic flow meter
type.
6.5.2
Entering master programming mode
1. Press and hold
or
until the programming icon
replaces the service icon and the parameter display reads TD.
2. Set the time to 12:01 PM with
or
.
3. Press
to validate the selection and return to the service
mode, or wait for 10 seconds.
4. Press and hold
and
for 5 seconds until the
programming icon replaces the service icon and the display
format screen appears.
Summary of Contents for FLECK 9000 SXT
Page 1: ...FLECK 9000 SXT INSTALLER MANUAL WATER PURIFICATION...
Page 78: ...Installer manual Fleck 9000 SXT Maintenance 78 118 Ref MKT IM 020 C 21 11 2019...
Page 80: ...Installer manual Fleck 9000 SXT Maintenance 80 118 Ref MKT IM 020 C 21 11 2019...
Page 82: ...Installer manual Fleck 9000 SXT Maintenance 82 118 Ref MKT IM 020 C 21 11 2019...
Page 85: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 85 118...
Page 87: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 87 118...
Page 89: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 89 118...
Page 92: ...Installer manual Fleck 9000 SXT Maintenance 92 118 Ref MKT IM 020 C 21 11 2019...
Page 118: ...www pentairaquaeurope com...