Installer manual Fleck 9000 SXT - Installation
Ref. MKT-IM-020 / C - 21.11.2019
47 / 118
5.12
Brine line connection
Mandatory
The brine line must be built with 3/8'' semi rigid piping !
Caution - material
Risk of malfunction due to the use of wrong equipment !
Flexible and semi-flexible hoses may shrink because of the vacuum during brine draw.
The brine line from the tank connects to the valve. Make the connections and hand tighten. Be
sure that the brine line is secure and free from air leaks. Even a small leak may cause the brine
line to drain out, and the softener will not draw brine from the tank. This may also introduce air
into the valve, causing problems with the valve operation.
Brine line must be equipped with brine tank air check in the brine tank.
Summary of Contents for FLECK 9000 SXT
Page 1: ...FLECK 9000 SXT INSTALLER MANUAL WATER PURIFICATION...
Page 78: ...Installer manual Fleck 9000 SXT Maintenance 78 118 Ref MKT IM 020 C 21 11 2019...
Page 80: ...Installer manual Fleck 9000 SXT Maintenance 80 118 Ref MKT IM 020 C 21 11 2019...
Page 82: ...Installer manual Fleck 9000 SXT Maintenance 82 118 Ref MKT IM 020 C 21 11 2019...
Page 85: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 85 118...
Page 87: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 87 118...
Page 89: ...Installer manual Fleck 9000 SXT Maintenance Ref MKT IM 020 C 21 11 2019 89 118...
Page 92: ...Installer manual Fleck 9000 SXT Maintenance 92 118 Ref MKT IM 020 C 21 11 2019...
Page 118: ...www pentairaquaeurope com...