background image

CONTROL VALVE ASSEMBLY

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

B

A

1

3

4

2

TITLE

SIZE

SCALE

SHEET 1 OF 1

DWG NO.

REV

CHECKED

APPROVED

APPROVALS

DATE

THIRD ANGLE

PROJECTION

DRAWN

VALVE / POWERHEAD ASSY 50DP AC SXT

SOFTENER

61500-50DP AC SXT

D

1:5

PS

5

D

C

6

7

8

6

7

8

B

C

D

B

A

DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]

INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009

UNLESS OTHERWISE SPECIFIED:

ALL FINISHED MACHINED SURFACES  125       OR BETTER.

TOLERANCES:

    

ANGLES :     

 1

  1 PLACE  .X:  

 .015  [0.38]

  2 PLACE  .XX:  

 .01  [0.3]

  3 PLACE  .XXX: 

 .005  [0.13]

BR42889

12/10/2019

Pentair Residential

Filtration, LLC

THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR

RESIDENTIAL FILTRATION, LLC.  REPRODUCTION, USE 

DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR

DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS 

PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR 

RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS 

DOCUMENT AND ANY COPIES SHALL BE RETURNED TO

PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.

  COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS

Item No.  QTY 

Part No. 

Description

 1 �������������������� 1 ����������18815 ��������������������� Valve Body Assy, 5000,  

1-inch Dist Down Flow 

 2 ������������������� 1 ����������18271 ��������������������� Screen Injector, 5800
 3 ������������������� 1 ����������40064 ������������������� Seal Injector
 4 ������������������� 1 ����������18277 ��������������������� Cap Injector
 5 �������������������2 ���������18262��������������������� Screw, Hex Washer Head, #10-24 x 1�00
 6 ������������������� 1 ����������19654��������������������� Label, 0�125 gpm Brine Flow
  

 ����������12128 ��������������������� Label, 0�25 gpm BLFC

  

 ����������10759 ��������������������� Label, 0�5 gpm 1�5 lbs Salt/Min

  

 ����������10760 �������������������� Label, 1�0 gpm 3 lbs Salt/Min

 7 ������������������� 1 ����������13333 ��������������������� Label, Injector, Blank
 8 �������������������3 ���������18261 ��������������������� Screw, Hex Washer Head, #10-24  0�81
 9 ������������������� 1 ����������13304 �������������������� O-ring, -121
 10 ����������������� 1 ����������18303-01 ���������������� O-ring, -336, 560CD
 11 ������������������ 1 ����������13030 �������������������� Retainer, Distributor Tube O-ring
 12 ������������������ 1 ����������18569 ��������������������� Retainer, Tank Seal
 13 ������������������ 1 ����������18312 ��������������������� DLFC Housing Retainer Clip
 14������������������ 1 ����������60115-001 �������������� Piston Assy, 5000, Std, D/F
 15������������������5 ����������44549 �������������������� Seal, Piston, 5000
 16������������������4 ����������14241 ��������������������� Spacer, 5600
 

17������������������ 1 ����������18264 �������������������� Spacer End, 5000

 18 ������������������ 1 ����������60032 �������������������� Brine Valve, 4600/5600
 19 ������������������ 1 ����������13302 �������������������� O-ring, -014
 20 �����������������������������60022-12 ��������������� BLFC, 0�125 gpm
  

 ����������60022-25 �������������� BLFC, 0�25 gpm

  

 ����������60022-50 �������������� BLFC, 0�5 gpm

  

 ����������60022-100 ������������� BLFC, 1�0 gpm

 21��������������������� ���������60705-00 �������������� DLFC, Plastic, Blank
  

 ����������60706-8�0 �������������� DLFC, QC x 3/4"F, 8�0 GPM

  

 ����������60706-9�0 �������������� DLFC, QC x 3/4"F, 9�0 GPM

  

 ����������60706-10 ��������������� DLFC, QC x 3/4"F, 10 GPM

  

 ����������60706-12 ��������������� DLFC, QC x 3/4"F, 12 GPM

  

 ����������60706-15 ��������������� DLFC, QC x 3/4"F, 15 GPM

 22 �����������������������������19153 ��������������������� Washer, Flow, 0�6 GPM
  

 ����������19152 ��������������������� Washer, Flow, 0�8 GPM

  

 ����������12085 �������������������� Washer, Flow, 1�2 GPM

  

 ����������19150 ��������������������� Washer, Flow, 1�3 GPM

  

 ����������12086 �������������������� Washer, Flow, 1�5 GPM

  

 ����������12087 ��������������������� Washer, Flow, 2�0 GPM

  

 ����������12088 �������������������� Washer, Flow, 2�4 GPM

  

 ����������12089 �������������������� Washer, Flow, 3�0 GPM

  

 ����������12090 �������������������� Washer, Flow, 3�5 GPM

  

 ����������12091 ��������������������� Washer, Flow, 4�0 GPM

  

 ����������19147 ��������������������� Washer, Flow, 4�5 GPM

  

 ����������12092 �������������������� Washer, Flow, 5�0 GPM

  

 ����������17814 ��������������������� Washer, Flow, 6�0 GPM

  

 ����������12408 �������������������� Washer, Flow, 7�0 GPM

 23 �����������������������������18272-000 ������������� Injector Assy, 1610, #000, Brown
  

 ����������18272-00 ��������������� Injector Assy, 1610, #00, Violet

  

 ����������18272-0 ����������������� Injector Assy, 1610, #0, Red

  

 ����������18272-1 ������������������ Injector Assy, 1610, #1, White

  

 ����������18272-2 ����������������� Injector Assy, 1610, #2, Blue

  

 ����������18272-3 ����������������� Injector Assy, 1610, #3, Yellow

 24 �����������������������������18276-01 ���������������� Injector Assy, Plug, w/O-rings

Not Shown:

  

 ����������40947-01 ��������������� Plug, Brine Valve, w/O-ring, 560CD

  

 ����������13918-01 ����������������� BLFC Module Plug Assy, w/O-ring

                        Excessive side load on piston rod may cause premature failure. 

                        If seal/spacer stack is stuck in valve bore during disassembly, 

rotate stack prior to removal.

CAUTION

CAUTION

PENTAIR FLECK 5000 Control Valve Service Manual 

• 

15

Summary of Contents for FLECK 5000

Page 1: ...pentair com FLECK 5000 CONTROL VALVE SERVICE MANUAL...

Page 2: ...0626 18 Paddle Meter Assembly P N 60086 50 18 Bypass Valve Assembly Metal 19 Bypass Valve Assembly Plastic 19 Safety Brine Valve 20 Dimensional Drawings 21 Water Conditioner Flow Diagrams 22 Injector...

Page 3: ...Outside Faucet Bath Tub Lavatory Toilet Kitchen Laundry Tubs Pump or Meter Hot Water Outlet Water Heater Brine Tank Overflow Drain Optional Floor Drain Drain Line Bypass Softener Grounding Strap Figur...

Page 4: ...hypochlorite 70 available chlorine is available in several forms including tablets and granules These solid materials may be used directly without dissolving before use 1 Dosage A Two grains approxima...

Page 5: ...13 mm Backwash flow rates in excess of 7 gpm 26 5 Lpm or length in excess of 20 feet 6 m require 3 4 inch 19 mm drain line Commercial drain lines should be the same size as the drain line flow control...

Page 6: ...Indicator Service Icon Programming Icon Extra Cycle Button Up Button Down Button Error Information Icon Features of the SXT Power backup that continues to keep time and the passage of days for a mini...

Page 7: ...normal operation Pressing the Extra Cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing Control Operation During Pro...

Page 8: ...ety Factor Percentage of the system capacity to be used as a reserve RC Fixed Reserve Capacity Fixed volume to be used as a reserve DO Day Override The system s day override setting RT Regen Time The...

Page 9: ...n entering Master Programming Mode The Display Format setting specifies the unit of measure that will be used for volume and how the control will display the Time of Day This option setting is identif...

Page 10: ...MING MODE CONTINUED 9 Safety Factor Display Code SF Press the Extra Cycle button Use this display to set the Safety Factor This setting specifies what percentage of the system capacity will be held as...

Page 11: ...ion for each day Use the Up and Down buttons to adjust the setting as needed Press the Extra Cycle button to accept the setting and move to the next day Note that the control requires at least one day...

Page 12: ...ds while in service and the time of day is NOT set to 12 01 PM 2 Use this display to adjust the Day Override This option setting is identified by DO in the upper left hand corner of the screen 3 Press...

Page 13: ...in service 2 Press the Up button Use this display to view the current Flow Rate This option setting is identified by FR in the upper left hand corner of the screen 3 Press the Up button Use this disp...

Page 14: ...r Downflow Softener U S Power Supply 1 Injector 0 50 GPM BLFC 500006 003 Turbine Meter B W Filter U S Power Supply NOTE NOTE Above part numbers DO NOT include the following parts Bypass Assembly Conne...

Page 15: ...sher Head 10 24 0 81 9 1 13304 O ring 121 10 1 18303 01 O ring 336 560CD 11 1 13030 Retainer Distributor Tube O ring 12 1 18569 Retainer Tank Seal 13 1 18312 DLFC Housing Retainer Clip 14 1 60115 001...

Page 16: ...4 Yoke SS NPT Washers 19153 Washer Flow 0 6 GPM 19152 Washer Flow 0 8 GPM 12085 Washer Flow 1 2 GPM 19150 Washer Flow 1 3 GPM 12086 Washer Flow 1 5 GPM 12087 Washer Flow 2 0 GPM 12088 Washer Flow 2 4...

Page 17: ...REQUIREMENT CHECKED 20 16 13 14 14 15 15 11 10 9 2 5 12 8 4 3 2 1 6 17 18 7 272481 A RELEASE FOR PRE PRODUCTION 44553 00 5000 44553 01 50DP 12 9 12 PWS ITEM NO PART NUMBER DESCRIPTION 44553 00 QTY 445...

Page 18: ...Item No QTY Part No Description 1 1 14716 Meter Cap Assy NT includes items 2 3 and 4 2 1 13874 Cap Meter Electronic 3 1 13847 O ring 137 Std Meter 4 1 17798 Screw Slot Hex Washer Head 5 1 19121 01 Met...

Page 19: ...Yoke 1 BSP Plastic 41027 02 Yoke 3 4 BSP Cast Machined 18706 12 Yoke 3 4 BSP Plastic 19620 01 Yoke Assy 3 4 R Angle 90 Deg 6 1 60049 Bypass Plastic Not Shown 2 19228 01 Adapter Assy Coupling w O ring...

Page 20: ...9647 Elbow Safety Brine Valve 9 2 19625 Nut Assy 3 8 Plastic 10 1 18312 Retainer Drain 11 1 60014 Safety Brine Valve Assy 2310 12 2 10150 Grommet 0 30 Dia 13 1 60068 30 Float Assy 2310 w 30 Rod 14 1 6...

Page 21: ...DIMENSIONAL DRAWINGS PENTAIR FLECK 5000 Control Valve Service Manual 21...

Page 22: ...neral in the mineral tank Conditioned water enters center tube through the bottom distributor then flows up through the center tube and to the outlet of the valve Hard water enters unit at valve inlet...

Page 23: ...ough nozzle and throat down through mineral and enters the center tube through bottom distributor and out through the drain line Hard water flows from inlet around the piston down through the mineral...

Page 24: ...TR18755 Rev B 24 PENTAIR FLECK 5000 Control Valve Service Manual INJECTOR FLOW DATA...

Page 25: ...BLACK ORANGE WT BLK BLACK WHITE GREEN BLUE BLUE WHITE BLUE WHITE BLUE PURPLE ORANGE BLACK WT BLK YELLOW BLACK BROWN METER P1 S N N H S VDO P2 N O H PWR H S CB1 50 60 HZ CB1 SXT Timer T1 24V Transforme...

Page 26: ...upport pentair com PENTAIR COM All indicated Pentair trademarks and logos are property of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owne...

Reviews: