4.  Fill the media tank with water.

A.  While the controller is in cycle C1 (Backwash), open the 

water supply valve very slowly to approximately the 1/4 

open position.

WARNING:

 If opened too rapidly or too far, media may 

be lost out of the tank into the valve or the 

plumbing. In the 1/4 open position, you should 

hear air slowly escaping from the valve  

drain line.

B.  When all of the air has been purged from the media 

tank (water begins to flow steadily from the drain line), 

open the main supply valve all of the way. This will 

purge the final air from the tank.

C.  Allow water to run to drain until the water runs clear 

from the drain line. This purges any refuse from the 

media bed.

D.  Turn off the water supply and let the system stand for 

about five minutes. This will allow any air trapped to 

escape from the tank.

5.  Add water to the regenerant tank (initial fill)  

(conditioner only).

A.  With a bucket or hose, add approximately 4 gallons (15 

liters) of water to the regenerant tank. If the tank has a 

salt platform in the bottom of the tank, add water until 

the water level is approximately 1 inch (25 mm) above 

the platform.

NOTE:   

We recommend that you do not put regenerant into 

the tank until after the control valve has been put into 

operation. With no regenerant in the tank, it is much 

easier to view water flow and motion in the tank.

6.  Engage the refill cycle to prime the line between the 

regenerant tank and the valve (conditioner only).

A.  Slowly open the main water supply valve again, to the 

fully open position. Be sure not to open too rapidly as 

that would push the media out of the media tank.

B.  Advance the controller to the Refill (C8) position. From 

cycle C1 (Backwash), press and hold the SET button. 

This will display the current cycle. 

While pressing the SET button, press UP to advance to 

the next cycle. Continue to advance through each cycle 

until you have reached cycle C8 (Refill).

NOTE:   

As you advance through each cycle there will be a 

slight delay before you can advance to the next cycle. 

The hourglass icon will light while the camshaft is 

indexing. There may be a pause at cycle C4 (System 

Pause). This cycle allows the water/air pressure to 

equalize on each side of the valve discs before moving 

on. The hourglass will not be visible indicating that 

the system is paused.

Time & Day

Regen Time & Day

Salt

SU MO TU WE TH FR SA DAYS

C

Capacity

Hardness

C.  With the water supply completely open, when you arrive 

at cycle C8 (Refill), the controller will direct water down 

through the line to the regenerant tank. Let the water 

flow through the line until all air bubbles have been 

purged from the line.

D.  Do not let the water flow down the line to the tank for 

more than one to two minutes, or the tank may overfill.

E.   Once the air is purged from the line, press the SET 

button and the UP button simultaneously to advance to 

cycle C0 (Treated Water) position.

7.  Draw water from the regenerant tank.

A.  From the treated water position (cycle C0), advance the 

valve to the draw regenerant position. Hold the REGEN 

button down for five seconds. 

The controller will begin a manual regen, and advance 

the control valve to the cycle C1 (Backwash). Press the 

SET and UP button to advance to cycle C2 (Draw).

B.  With the controller in this position, check to see that 

the water in the regenerant tank is being drawn out of 

the tank. The water level in the tank should recede  

very slowly.

C.  Observe the water being drawn from the regenerant 

tank for at least three minutes. If the water level does 

not recede, or goes up, check all hose connections. C2 

should be displayed.

8.  If the water level is receding from the regenerant tank 

you can then advance the controller back to the treated 

water (C0) position by pressing SET and the UP buttons 

simultaneously to advance the controller to the C0 position.

9.  Finally, turn on a faucet plumbed after the water 

conditioner. Run the faucet until the water runs clear. Add 

regenerant to the regenerant tank.

Things You Might Need to Know

• 

When the controller is first plugged in, it may display a 

flashing hourglass and the message Err 3, this means 

that the controller is rotating to the home position. If 

the Err 2 is displayed, check that the incoming power 

frequency matches the controller. The North American 

controller will not run with 50 Hz input.

• 

The preset default time of regeneration is 2:00 AM.

• 

English or Metric? The World controller senses the 

electrical input and decides which is needed. The North 

American controller only runs on 60 Hz and defaults to 

English units.

• 

The 700 Series controller can be programmed to 

regenerate on specific days of the week.

• 

If electrical power is not available, the camshaft can be 

rotated counterclockwise by hand if the motor is removed.

• 

The 700 Series controllers send commands to the motor 

for camshaft movement. However, water pressure/flow 

are required during the regeneration cycle for backwash, 

purge and refill, and brine draw to actually take place.

• 

Make sure control power source is plugged in. The 

transformer should be connected to a non-switched 

power source.

• 

You can start programming at the beginning by resetting 

the amount of media. When viewing H0 (History Value) 

push and hold SET for five seconds. The display reverts 

back to --- and any programmed information is lost. 

Return to Initial Power Up.

SYSTEM START UP 

CONTINUED

18

 

• 

AUTOTROL

®

 740/760 Control 255 & Performa Series Valves (268, 268FA) Service Manual

Summary of Contents for AUTOTROL 740

Page 1: ...AUTOTROL 740 760 CONTROL 255 PERFORMA SERIES VALVES 268 268 FA SERVICE MANUAL www pentairaqua com...

Page 2: ...used on connections that do not use an O ring seal Do not use pliers or pipe wrenches All plumbing must be completed according to local codes Soldering near the drain line should be done before connec...

Page 3: ...port valve outlet to spin the turbine The controller will verify that the turbine works and the self test will finish Proceed with the initial start up procedure Initial Start up Step by step Instruc...

Page 4: ...TH FR SA DAYS Capacity Hardness Low Setting High Efficiency Set desired regenerant amount Default setting is S standard salting 3 salt settings are available on 740 and 760 controls S Standard Salt 9...

Page 5: ...t SET and UP to advance through each cycle Press and hold SET and UP buttons for 5 seconds to cancel regen Hourglass will begin flashing indicating regen is cancelled Camshaft will advance to home may...

Page 6: ...ested and Certified by WQA to NSF ANSI Std 61 Section 8 Mechanical Devices WQA Certified 255 Valve Systems WQA Certified 268 Valve Systems 255 740 075 844 268 740 948 255 740 100 948 268 740 150 1054...

Page 7: ...sted by WQA and conform to NSF ANSI 44 for specific performance claims as verified and substantiated by test data These systems are not intended to be used for treating water that is microbiologically...

Page 8: ...less that 3350 grains of total hardness exchanged per pound of salt based on NaCl equivalency 477 grams of total hardness exchanged per kilogram of salt and shall not deliver more salt than its liste...

Page 9: ...NSI 44 for specific performance claims as verified and substantiated by test data These systems are not intended to be used for treating water that is microbiologically unsafe or of unknown quality wi...

Page 10: ...that 3350 grains of total hardness exchanged per pound of salt based on NaCl equivalency 477 grams of total hardness exchanged per kilogram of salt and shall not deliver more salt than its listed rati...

Page 11: ...er Bypass Flapper Open Cycle C4 This cycle closes the flappers for a short time to allow the air and water to hydraulically balance in the valve before continuing the regeneration 5 Fast Rinse Downflo...

Page 12: ...r 34 F 1 C and below 120 F 49 C Water pressure below 125 psi 8 61 bar and above 20 psi 1 4 bar In Canada the water pressure must be below 100 psi 6 89 bar Constant electrical supply to operate the con...

Page 13: ...itioner Figure 7 Typical Globe Valve Bypass System WARNING The inlet water must be connected to the inlet port of the valve When replacing non Pentair Water valves the inlet and outlet may be reversed...

Page 14: ...Drain Secure hose in place Drain Tubing Overflow Fitting Figure 9 Overflow Line Connection Regenerant Line Connection not used with filter system The regenerant line from the tank connects to the valv...

Page 15: ...play The World controller will sense the input power as 50 or 60 Hz and operate accordingly Controller Location The 700 Series controllers are designed to be mounted on the valve or attached to a flat...

Page 16: ...u ve selected If incorrect setting is programmed see Resetting the Control section below NOTE If the controller was incorrectly set to the wrong valve body press the DOWN button and SET button for fiv...

Page 17: ...acity Hardness System capacity is displayed in total kilograins or kilograms of hardness removed before a regeneration is necessary Value is derived from the system s resin volume input and salt amoun...

Page 18: ...m the line D Do not let the water flow down the line to the tank for more than one to two minutes or the tank may overfill E Once the air is purged from the line press the SET button and the UP button...

Page 19: ...powered up for the first time Variable Reserve Function The 700 Series metered demand volumetric controllers 760 and 760C are designed to have a variable reserve feature This feature automatically ad...

Page 20: ...regenerate button immediately returns the controller to normal operation Programming Conventions The 700 Series controller is programmed using the buttons on the keypad The programming instructions w...

Page 21: ...ious programming sections Days Between Regeneration Setting 740 FA To set the days between regenerations consult the media manufacturer for the actual capacity of the media In general manganese greens...

Page 22: ...cription Range H0 Resin volume initial setting value Cubic feet or liters H1 Days since last regeneration 0 255 H2 Current flow rate 0 47 GPM or 0 177 LPM H3 Water used today in gallons m3 since Time...

Page 23: ...tion Key Duration Display Enter Level II programming UP and DOWN 5 sec P1 display Return to operation UP and DOWN 5 sec Time and day of week Increment through menus UP and DOWN P R Next parameter disp...

Page 24: ...back into one site To install control module Wire Clips Slots for Motor and Turbine Harness 1 Be sure the power is disconnected 2 Check model 3 Check routing of wires and plug them into the controlle...

Page 25: ...le in the hollow of the cup An arrow on the top plate points to the current marking The numbers represent regeneration cycles as follows C0 Treated water normal operation mode C1 Backwash C2 Regeneran...

Page 26: ...This switch is turned on off by a cam lobe on the camshaft Its function is to signal that the unit is in service or out of service regenerating Microswitches are available as kits from Pentair Water o...

Page 27: ...ack further to remove the spring To install spring 7 5 6 6 1 Inspect the spring for damage Do not attempt to repair a bent spring 2 Position yourself on the spring side of the valve discs 3 Position t...

Page 28: ...mpletely into the port cavity 3 The metal portion will be positioned straight up and the top of the shoulder will be level with the valve To install the top plate 1 5 9 13 17 15 11 7 3 4 8 12 16 18 14...

Page 29: ...those sold for commercial laundries adjust the dosage accordingly 1 Dosage F Polystyrene resin 1 2 fluid ounce 35 5 ml per cubic foot G Non resinous exchangers 0 8 fluid ounce 23 7 ml per cubic foot...

Page 30: ...AMS 255 Valve 1 10 8 9 7 6 5 4 3 2 11 18A 19 17A 16 15 14 13 12 20 21 17B 20 18B WARNING Do not use flow control ball with 17B or 18A 30 AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA S...

Page 31: ...High Efficiency Tan 8 inch tank 1035733 H Injector High Efficiency Lt Purple 9 inch tank 1035734 J Injector High Efficiency Lt Blue 10 inch tank 1035735 K Injector High Efficiency Pink 12 inch tank 10...

Page 32: ...9 Bypass Body Assembly with Install Kit 1040524 Bypass Installation Kit Tube Adapter Kits 1 1001606 3 4 inch Copper Tube Adapter Kit 1 1001670 1 inch Copper Tube Adapter Kit 1 1001608 22 mm Copper Tub...

Page 33: ...ONTINUED Performa Valve 1 10A 8 9 7 6A 5 4 3 2 11 18 19 17 16 15 14 13 12 6B 10B WARNING Do not use the flow control ball with 6B or 10A 11 AUTOTROL 740 760 Control 255 Performa Series Valves 268 268F...

Page 34: ...gpm 34 Lpm 1030360 Drain Line Flow Control 10 gpm 38 Lpm 7 1 3019221 Motor Optical Cable Assembly 8 1 1000226 Screen Cap Assembly w O Ring 9 1 Injector High Efficiency Options 1035730 E Injector HIgh...

Page 35: ...ter Kit 3023824 3 4 inch BSPT SS Pipe Adapter Kit 3023828 1 inch NPT SS Pipe Adapter Kit 3023807 1 inch BSPT SS Pipe Adapter Kit 17 1 1001986 13 16 inch Rubber Insert Optional 18 1 1235446 Turbine Cab...

Page 36: ...cal Components 3019221 Motor Optical Cable Assembly 700 Series Control 60 Hz 2 AC Adapter 1000810 Japanese 1000811 North American 1000812 Australian 1000813 British 1000814 European 1030234 Transforme...

Page 37: ...haft is not turning during ERR 3 display Check that motor is connected Verify that motor wire harness is connected to motor and controller module Verify that optical sensor is connected and in place V...

Page 38: ...er pressure Set pump to maintain 20 psi at softener Restricted drain line Change drain to remove restriction Injector plugged Clean injector and screen Injector defective Replace injector Contact deal...

Page 39: ...nd flush with clean water Turbine should spin freely if not replace meter Contact dealer Regenerant tank overflow Regenerant valve disc 1 being held open by foreign matter Manually operate valve stem...

Page 40: ...Check 1 5 2 4 Valve No 1 Open 2 Closed 3 Closed 4 Open 5 Open 6 Closed Backwash Position Brine Tank Mineral Tank Drain Inlet Outlet Hard Water Soft Water 3 6 Drain Control 6 Air Check 5 2 4 1 Valve No...

Page 41: ...Tank Drain Inlet Outlet Hard Water Soft Water 5 3 1 2 4 6 Drain Control 6 Air Check Valve No 1 Open 2 Open 3 Open 4 Closed 5 Closed 6 Closed Fast Rinse Position Brine Tank Mineral Tank Drain Inlet Ou...

Page 42: ...en 3 Closed 4 Closed 5 Closed 6 Open 7 Closed Backwash Position Brine Tank Mineral Tank Drain Inlet Outlet Hard Water Soft Water 5 4 1 3 2 6 7 Backwash Flow Control Valve No 1 Closed 2 Open 3 Closed 4...

Page 43: ...5 B A C K W A S H F L O W C v 1 2 0 LWR 4630 SVC LWR 5236 BW 2 6 4 8 10 12 16 14 0 0 9 1 4 1 8 0 5 0 2 3 2 7 3 2 3 6 1 10 1 00 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 00 16 14 12 10 8 6 4 2 0...

Page 44: ...0 0 20 0 10 0 00 LWR6151 20 2 3 5 5 6 7 5 40 60 80 100 120 Injector H Light Purple For 9 inch Tanks 0 18 0 16 0 14 0 12 0 10 0 08 0 06 0 04 0 02 0 00 m 3 hr 0 80 0 60 0 40 0 20 0 00 LWR6151 20 2 3 5 5...

Page 45: ...AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual 45...

Page 46: ...46 AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual...

Page 47: ...AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual 47...

Page 48: ...s and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice Pentair...

Reviews: