700 Series Advanced Programming
For Regeneration
SET
UP arrow
DOWN
arrow
The 700 Series controllers are designed to operate by only
setting the time of day and the day of the week. The remaining
settings have been set at the factory. These default settings
will work for most applications.
To change a setting:
Action
Key
Duration
Display
Enter basic
programming
SET
Press and
Release
Will show day of
week
Move to
desired
display
UP or DOWN
arrows
Press and
Release
Will increment
through the
displays
Enable setting
to be changed
SET
Press and
Release
Display will flash
Change
setting
UP or DOWN
arrows
Press and
Release
Value changes and
continues to flash
Save setting
SET
Press and
Release
Display stops
flashing
Return to
operation
REGEN
Press and
Release
Normal operation
display
View history
values
SET and
DOWN
Press and Hold
for 5 seconds
HO will be
displayed
This level of programming is accessible by pressing the SET
button. The UP and DOWN arrows will step through the settings:
Time of day
Day of week
Time of regeneration
Number of days between regeneration (99 day timer)
Day of week regeneration (displays only when number of days
between regeneration equals zero) (7 day timer)
Amount of regenerant used per regeneration or filter
backwash time
System capacity (view only)
Accessing History Values
The Logix control features a review level that displays the
operation history of the system. This is a great troubleshooting
tool for the control valve.
To access history values, press and hold SET and DOWN for
five seconds to view the "H" levels.
History Values
Description
Range
H0
Resin volume initial setting
value
Cubic feet or liters
H1
Days since last regeneration
0 – 255
H2
Current flow rate
0 – 47 GPM or 0 – 177 LPM
H3
Water used today in gallons/m
3
since Time of Regeneration
0 – 65536 gallons or
0 – 6553.6 m
3
H4
Water used since last
regeneration in gallons/m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H5
Total water used since reset in
100s
0 – 65536 gallons or
0 – 6553.6 m
3
H6
Total water used since reset in
1,000,000
0 – 65536 gallons or
0 – 6553.6 m
3
H7
Average usage for Sunday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H8
Average usage for Monday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H9
Average usage for Tuesday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H10 Average usage for Wednesday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H11 Average usage for Thursday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H12 Average usage for Friday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
H13 Average usage for Saturday in
gallons or m
3
0 – 65536 gallons or
0 – 6553.6 m
3
Resetting the Logix Control
To reset the control:
1. Press and hold SET and DOWN simultaneously for 5 seconds.
2. H0 and the system’s set resin volume (or “F” mode) will
be displayed.
3. If a history value other the “H0” is displayed, use the UP
button to scroll through the settings until “H0” is displayed.
4. To reset the control, press and hold SET for 5 seconds.
5. The control will be reset to an unprogrammed state.
6. Go to “Initial Set-up” section to reprogram control.
WARNING:
Resetting the control will delete all information
stored in its memory, except time and day.
This will require you to reprogram the control
completely from the initial power-up mode.
PROGRAMMING
CONTINUED
22
•
AUTOTROL
®