Secondary drainage

Secondary drainage can be provided by drilling holes (Ø 5mm) 
all round the edge above the sealing membrane.

Information

 on sealants and adhesives can be found in the in-

formation sheet on "Composite sealing" issued by the profes-
sional association of the German tile industry within the Ger-
man Construction Confederation (ZDB). 
Differences in height between individual tiles can be offset by 
adjusting the plastic screws under the lid element. 
For aesthetic reasons, the edge covers included in the pack-

age can be fitted.

Both of the stainless steel cover elements (a) can also be com-
pletely tiled over (b). To do so, just turn the larger element over, 
and use the smaller element without a drain. 

Notice!

 Do not seal the inner side of the gap that runs around 

the edge.

MAINTENANCE

WARNING!

Before carrying out any work, always disconnect the Plancofix 

from the power supply and ensure that it cannot be switched 
on again by other persons.
The system is largely maintenance-free. However, soap resi-
dues should be removed from the interior of the tank every 2-3 
weeks. To do so, simply lift the cover off and then clean the 
inside carefully with a paintbrush.

The float may only be pulled up at the small nose up to the per

-

ceptible resistance!

NOTICE!

 Do not use aggressive drain cleaners! 

If the hydraulic system is blocked, pull the red fixing element 

upwards and take it out. Next, gently loosen the hydraulic sys-
tem and remove it. After cleaning, make sure that when you 
re-insert it, the swing-type check valve and the two seals are 

firmly in place. Finally, insert the red fixing element. 

5

Summary of Contents for PLANCOFIX LINE

Page 1: ...EN Instruction Manual JUNG PUMPEN DE B 45155 32 1902 PLANCOFIX PLANCOFIXPLUS...

Page 2: ...ng this information can be dangerous General danger to people Warning of electrical voltage NOTICE Danger to equipment and operation Qualification and training of personnel All personnel involved with...

Page 3: ...ugging it from the mains or turning off the main switch or triggering the FI cir cuit breaker and ensure that the power supply to the unit can not be switched on again by anyone else NOTICE Never put...

Page 4: ...around the outlet Acoustically isolate the pressure pipe connect it to the pressure outlet with a 1 female thread and route it to the nearest downpipe Notice Tighten the fitting carefully to avoid dam...

Page 5: ...thout a drain Notice Do not seal the inner side of the gap that runs around the edge MAINTENANCE WARNING Before carrying out any work always disconnect the Plancofix from the power supply and ensure t...

Page 6: ...2008 EN 61000 3 2 2014 EN 61000 3 3 2013 DE Richtlinien Harmonisierte Normen CS Sm rnice Harmonizovan normy DA Direktiv Harmoniseret standard EN Directives Harmonised standards FI Direktiivi Yhdenmuk...

Page 7: ...Plancofix Plancofix plus 7...

Page 8: ...85 Abdeckung Cover JP45594 Abdeckung klein Cover small JP45595 Ablaufrost Grid JP45596 Deckel Motorraum Cover for motor JP45597 Schwimmer Float JP45598 Mikroschalter Micro switch JP45599 Schaltwelle S...

Page 9: ...l JP45595 Ablaufrost Grid JP45596 Schwimmer Float JP45598 Deckel Motorraum Cover for motor JP45597 Mikroschalter Micro switch JP45599 Schaltwelle Switch cam JP48072 Netzleitung Cable JP45603 Motorspan...

Page 10: ...arks of Pentair or its subsidiaries in the United States and or other countries 2019 Pentair Jung Pumpen Pump Technical Services Limited Pump House Unit 12 Bilton Road Industrial Estate Erith Kent DA8...

Reviews: