background image

ENGLISH

wherever you are working.
Make sure that there are no toxic gases in the working area.
Observe the health and safety at work regulations and make 

sure that a first­aid kit is to hand.

In some cases, the pump and the pumping medium may be hot 
and could cause burns. 
For installations in areas subject to explosion hazards, special 
regulations apply! 

APPLICATION

Plancofix is a floor drainage pump that allows grey water to be 

pumped out of a domestic walk-in shower if a gravity sewer 

system is  not  available.  The Plancofix  is fitted  directly under 

the shower. 
The temperature of the shower water must not exceed 40°C.

The Plancofix must not be used as back­flow protection or for 

discharging other drainage units.
Use of the pumps is subject to relevant national laws, regula-
tions and local requirements such as:

   

Domestic contaminated water and waste water (e.g. EN 

12056 in Europe )

   

Installation of low voltage systems  

(e.g. VDE 0100 in Germany)

Further regulations must be observed (e.g. VDE 0100 in Ger-
many, part 701:  bathrooms and shower rooms)
Noise emission value < 70 dB(A)

ELECTRICAL CONNECTION

NOTICE!

 Electrical work on the Plancofix must be carried out 

by a qualified electrician only. 

WARNING!

Before carrying out any work, disconnect the unit completely 
from the mains power supply (e.g. by unplugging it from the 
mains, or turning off the main switch, or triggering the FI cir-
cuit breaker) and ensure that the power supply to the unit can-
not be switched on again by anyone else.

NOTICE! 

Never put the free end of the cable in water! If water 

gets into it, this can cause malfunctions and damage.

Current applicable standards (such as EN standards), national 
regulations (such as VDE in Germany), and the regulations of 
the local power supply companies must be complied with.
Observe the operating voltage (see type plate)! Only connect 
the pump to electrical circuits that have been installed prop-

erly in accordance with the regulations and are fitted with at 

least a 10 A (delay) fuse and an FI circuit breaker (30 mA). 
The pump is provided with a winding thermostat. In case of un-
acceptably high temperatures, it switches off the pump to pro-
tect it against possible damage. Unacceptably high tempera-
tures may result, for example, from dry running, or mechanical 
or electrical overload.

INSTALLATION

The Plancofix is recessed entirely into the floor. The unit can 

be accessed for maintenance through the top cover (tiled or 

stainless steel finish). 
A sufficiently deep 40 x 40 cm recess must be created for the 

tank. 

NOTICE!

 Make sure that the existing concrete floor is suffici

-

ently thick and that the structural conditions allow a recess to 
be made. 

Conduits must be created for the pressure pipe and electricity 
supply cable, 1" FPT pressure pipe outlet, 3/4" cable conduit. 

Installation beside the shower

3

Summary of Contents for PLANCOFIX LINE

Page 1: ...EN Instruction Manual JUNG PUMPEN DE B 45155 32 1902 PLANCOFIX PLANCOFIXPLUS...

Page 2: ...ng this information can be dangerous General danger to people Warning of electrical voltage NOTICE Danger to equipment and operation Qualification and training of personnel All personnel involved with...

Page 3: ...ugging it from the mains or turning off the main switch or triggering the FI cir cuit breaker and ensure that the power supply to the unit can not be switched on again by anyone else NOTICE Never put...

Page 4: ...around the outlet Acoustically isolate the pressure pipe connect it to the pressure outlet with a 1 female thread and route it to the nearest downpipe Notice Tighten the fitting carefully to avoid dam...

Page 5: ...thout a drain Notice Do not seal the inner side of the gap that runs around the edge MAINTENANCE WARNING Before carrying out any work always disconnect the Plancofix from the power supply and ensure t...

Page 6: ...2008 EN 61000 3 2 2014 EN 61000 3 3 2013 DE Richtlinien Harmonisierte Normen CS Sm rnice Harmonizovan normy DA Direktiv Harmoniseret standard EN Directives Harmonised standards FI Direktiivi Yhdenmuk...

Page 7: ...Plancofix Plancofix plus 7...

Page 8: ...85 Abdeckung Cover JP45594 Abdeckung klein Cover small JP45595 Ablaufrost Grid JP45596 Deckel Motorraum Cover for motor JP45597 Schwimmer Float JP45598 Mikroschalter Micro switch JP45599 Schaltwelle S...

Page 9: ...l JP45595 Ablaufrost Grid JP45596 Schwimmer Float JP45598 Deckel Motorraum Cover for motor JP45597 Mikroschalter Micro switch JP45599 Schaltwelle Switch cam JP48072 Netzleitung Cable JP45603 Motorspan...

Page 10: ...arks of Pentair or its subsidiaries in the United States and or other countries 2019 Pentair Jung Pumpen Pump Technical Services Limited Pump House Unit 12 Bilton Road Industrial Estate Erith Kent DA8...