background image

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury!

DANGER 

warns about hazards that 

will

cause serious personal injury, death or major property
damage if ignored.

WARNING 

warns about hazards that 

can

cause serious personal injury, death or major property
damage if ignored.

CAUTION 

warns about hazards that 

will

or

can

cause minor personal injury or property damage if

ignored.
The word 

NOTICE 

indicates special instructions which

are important but not related to hazards.
1. To avoid risk of serious bodily injury and property

damage, read safety instructions carefully before
installing pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump.

3.

To avoid fatal shocks, proceed as fol-

lows if pump needs servicing:

A.

Disconnect power to pump outlet box before
pulling pump cord plug.

After plug is pulled, let

pump cool for 20 minutes before attempting to
work on it.

B.

Take extreme care when changing fuses. 

To re-

duce chance of fatal electrical shocks, 

DO NOT

stand in water or put your finger in the fuse socket.

C.

Ground

electrical outlet box.

D.

Use only Ground Fault Circuit Interrupter (GFCI)
protected grounded outlet

for cord plug.

4.

Never run pump dry. 

To do so can damage internal

parts, overheat pump (which can cause burns to people
handling or servicing pump), and will void warranty!

5.

Risk of fire or explosion from sparks

from motor brushes.

Do not pump gasoline or any

other flammable liquids with pump. Do not use pump
in  atmosphere that might contain flammable fumes or
vapors.

6. Do not pump chemicals or corrosive liquids with

pump.

If water is trapped in pump during opera-

tion, it may turn to steam, leading to explosion and
burns. Never run pump with outlet shut off or blocked.

NOTICE

Pump clean water only with pump. To avoid clogging
pump and damage to shaft seal, do not pump water con-
taining solids, foreign material, sand, silt, or abrasives.
Always have suction strainer installed when pump is
operating. Failure to use strainer may cause pump failure
and void warranty.
Clean strainer and flush out pump after each use.
Make sure all hose and pipe connections in suction line
are tight. An air leak in suction line will prevent priming
and reduce performance.
To prevent damage to pump materials, do not use pipe
joint compounds on pump ports. Use only teflon tape or
Plasto-Joint-Stik* to seal threads.
Tighten all piping to pump hand tight +1-1/2 turns only.
Overtightening may break pump and will void warranty.
Maximum liquid temperature is 120˚F (48.8˚C).

*Lake Chemical Co., Chicago, Illinois

Safety

2

Pump is supplied with

3-conductor grounding

type cord. Connect only to
properly grounded, GFCI
protected outlet. Do not lift
pump by electrical cord. Do
not use an extension cord.

Pump is non-sub-

mersible. Keep motor

dry at all times. Do not wash
motor. Do not immerse. 
Protect motor from wet
weather.

Unplug pump before

servicing.

Hazardous voltage.
Can shock, burn,
or cause death.

Ground pump before
connecting to
power supply.

Risk of fatal electrical shock if pump
motor gets wet.
Keep motor dry.

Do not immerse pump or motor, or run
pump if motor is wet.

Summary of Contents for HTP50

Page 1: ...mantenimiento de la bomba Llame al 1 888 957 8677 Espa ol Paginas 16 22 HYD819 Rev 7 28 09 IN OUT Model HTP50 Risk of fatal electrical shock if pump motor gets wet Keep motor dry Do not immerse pump o...

Page 2: ...plosion from sparks from motor brushes Do not pump gasoline or any other flammable liquids with pump Do not use pump in atmosphere that might contain flammable fumes or vapors 6 Do not pump chemicals...

Page 3: ...anty service through the installing dealer as soon as a problem is discovered No request for service will be accepted if received after the Warranty Period has expired This warranty is not transferabl...

Page 4: ...atal electric shock Unplug pump before servicing it Do not handle pump or attempt to work on pump with wet hands or while standing on wet or damp floor Plug pump into 115 Volt 60 Cycle outlet only Pum...

Page 5: ...are cut O Ring Key No 4C from the assembly 4 Unscrew the impeller Key No 4A from the motor shaft and discard it 5 Pull the seal plate Key No 5 from the motor shaft 6 Turn the seal plate face down See...

Page 6: ...ns carefully to be sure that no bare copper shows If you see any bare wire disconnect the wire nut and remake that connection 7 Once you are sure that there is no exposed wire carefully stuff the wire...

Page 7: ...OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT A B IN OUT IN OUT IN OUT IN OUT 5605 0407 IN OUT 5606 0407 IN OUT 5607 0407 Step 1 Step 2 IN IN IN OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT IN OUT IN OUT...

Page 8: ...are Cut O Ring 1 5 Seal Plate 1 6 Handle With Hardware 1 C54 30 7 Power Cord 1 PS17 1507 8 Brush Kit Includes 1 Pair of Brushes with springs and Retainer Caps 1 FPPKG 226 P2 9 Motor 1 If Pump Body or...

Page 9: ...mable avec cette pompe ni l utiliser dans un environnement pou vant contenir des vapeurs ou gaz inflammables 6 Ne pas pomper de produits chimiques ou corrosifs avec cette pompe Si de l eau est retenue...

Page 10: ...installation d s qu un probl me est d couvert pour obtenir un service sous garantie Aucune demande de service en vertu de sa garantie ne sera accept e apr s expiration de la dur e de sa garantie Ces...

Page 11: ...ur une sortie de 115 volts 60 cycles Cette pompe est quip e d un c ble et d une prise 3 fils m talliques et masse Ne pas modifier ni ter la prise Ne brancher qu une sortie correctement mise masse Veil...

Page 12: ...D poser le joint torique taille carr e R f 4C de l ensemble 4 D visser l impulseur R f 4A de l arbre du moteur puis le jeter 5 Sortir la plaque d tanch it R f 5 de l arbre du moteur 6 Tourner la plaq...

Page 13: ...nu n est expos Si un fil nu est expos d poser le serre fil et refaire la connexion 7 D s qu on est s r qu aucun fil nu n est expos pousser prudemment les fils et les serre fils dans la cavit du moteu...

Page 14: ...IN IN IN OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT A B IN OUT IN OUT IN OUT IN OUT 5605 0407 IN OUT 5606 0407 IN OUT 5607 0407 tape 1 tape 2 IN IN IN OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT IN OU...

Page 15: ...h it 1 6 Poign e et fixations 1 C54 30 7 Cordon lectrique 1 PS17 1507 8 Trousse de balais comprend 1 paire de balais les ressorts et 1 FPPKG 226 P2 les bouchons 9 Moteur 1 Si le corps de la pompe ou s...

Page 16: ...l motor No bombee gasolina ni ning n otro l quido inflamable No use la bomba en una atm sfera que pueda contener humos o vapores inflamables 6 No bombee productos qu micos o l quidos corrosivos Si que...

Page 17: ...y deber solicitar el servicio bajo garant a a trav s del concesionario instalador tan pronto como se descubra un problema No se aceptar ninguna solicitud de servicio bajo garant a que se reciba despu...

Page 18: ...rriente de 115 voltios y 60 ciclos La bomba est equipada con un cord n de 3 conductores conectado a tierra y un enchufe No modifique ni quite el enchufe Enchufe el cord n en una toma de corri ente con...

Page 19: ...la unidad de la bomba del motor Saque el aro t rico de corte recto usado Referencia No 4C de la unidad 4 Destornille el impulsor Referencia No 4A del eje del motor y desc rtelo 5 Saque la placa de est...

Page 20: ...o est seguro de que no haya hilos expuestos cuidadosamente introduzca los cables y los conec tores del cable nuevamente en la cavidad del motor 8 Sostenga la placa del cord n contra el motor y vuel va...

Page 21: ...IN IN IN OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT A B IN OUT IN OUT IN OUT IN OUT 5605 0407 IN OUT 5606 0407 IN OUT 5607 0407 Paso 1 Paso 2 IN IN IN OUT OUT OUT 5604 0407 IN IN IN OUT OUT OUT IN OU...

Page 22: ...go con accesorios de ferreter a 1 C54 30 7 Cord n el ctrico 1 PS17 1507 8 Juego de escobillas Incluye 1 par de escobillas con resortes y casquetes de retenci n 1 FPPKG 226 P2 9 Motor 1 Si la Unidad de...

Page 23: ...23...

Page 24: ......

Reviews: