background image

10

  

E-03-577 (01-23-20)

Item

4-Pole 1750 RPM

10 – 15 hp

208-230/3/60

10 – 15 hp

460/3/60

10 – 15 hp

575/3/60

5 – 7.5 hp

208-230/1/60

5 – 7.5 hp

208-230/3/60

5 – 7.5 hp

460/3/60

5 – 7.5 hp

575/3/60

A1

STATOR

27886D003

27886D003

27886D603

27885D001

27884D003

27884D003

27884D603

A2 ROTOR/SHAFT ASSEMBLY

27886D011

27886D011

27886D011

27885D011

27884D011

27884D011

27884D011

A3

BOLT

 – 

STATOR (4)

06106A070

06106A070

06106A070

001780051

001780041

001780041

001780041

A4

SPACER

007362141

007362141

007362141

007362141

CONNECTOR

12672A001

12672A001

Item

2-Pole 3450 RPM

10 – 15 hp

208-230/3/60

10 – 15 hp

460/3/60

10 – 15 hp

575/3/60

7.5 hp

208-230/3/60

7.5 hp

460/3/60

7.5 hp

575/3/60

A1

STATOR

27889D003

27889D003

27889D603

27887D003

27887D003

27887D603

A2

ROTOR/SHAFT 

ASSEMBLY

27887D011

27887D011

27887D011

27887D011

27887D011

27887D011

A3

BOLT – STATOR (4)

001780051

001780051

001780051

001780051

001780051

001780051

A4

SPACER

007362141

007362141

007362141

007362141

007362141

007362141

CONNECTOR

12672A001

12672A001

Item

6-Pole 1150 RPM

3 – 5 hp

208-230/3/60

3 – 5 hp

460/3/60

3 – 5 hp

575/3/60

A1

STATOR

27883D003

27883D003

27883D603

A2 ROTOR/SHAFT ASSEMBLY

27883D011

27883D011

27883D011

A3

BOLT – STATOR (4)

001780051

001780051

001780051

A4

SPACER

007362141

007362141

007362141

CONNECTOR

12672A001

IMPELLER PARTS LIST

Description

HP

Voltage/PH

Cord

Trim

Impeller

  1750 RPM

H3H(X)P500BC

5

208/1

8-4

7.50

151465102

H3H(X)P500CC

5

230/1

8-4

7.50

151465102

H3H(X)P500DC

5

208/3

10-4

7.50

151465102

H3H(X)P500EC

5

230/3

10-4

7.50

151465102

H3H(X)P500FC

5

460/3

10-4

7.50

151465102

H3H(X)P500GC

5

575/3

10-4

7.50

151465102

H3H(X)P750CC

7.5

230/1

8-4

8.00

151465082

H3H(X)P750DC

7.5

208/3

8-4

8.00

151465082

H3H(X)P750EC

7.5

230/3

8-4

8.00

151465082

H3H(X)P750FC

7.5

460/3

10-4

8.00

151465082

H3H(X)P750GC

7.5

575/3

10-4

8.00

151465082

H3H(X)P1000DC

10

208/3

8-4

8.50

151465062

H3H(X)P1000EC

10

230/3

8-4

8.50

151465062

H3H(X)P1000FC

10

460/3

10-4

8.50

151465062

H3H(X)P1000GC

10

575/3

10-4

8.50

151465062

H3H(X)P1500DC

15

208/3

8-4

10.00

151465002

H3H(X)P1500EC

15

230/3

8-4

10.00

151465002

H3H(X)P1500FC

15

460/3

8-4

10.00

151465002

H3H(X)P1500GC

15

575/3

10-4

10.00

151465002

Description

HP

Voltage/PH

Cord

Trim

Impeller

  1750 RPM

H4H(X)P500BC

5

208/1

8-4

7.50

151465102

H4H(X)P500CC

5

230/1

8-4

7.50

151465102

H4H(X)P500DC

5

208/3

10-4

7.50

151465102

H4H(X)P500EC

5

230/3

10-4

7.50

151465102

H4H(X)P500FC

5

460/3

10-4

7.50

151465102

H4H(X)P500GC

5

575/3

10-4

7.50

151465102

H4H(X)P750CC

7.5

230/1

8-4

8.00

151465082

H4H(X)P750DC

7.5

208/3

8-4

8.00

151465082

H4H(X)P750EC

7.5

230/3

8-4

8.00

151465082

H4H(X)P750FC

7.5

460/3

10-4

8.00

151465082

H4H(X)P750GC

7.5

575/3

10-4

8.00

151465082

H4H(X)P1000DC

10

208/3

8-4

8.63

151465142

H4H(X)P1000EC

10

230/3

8-4

8.63

151465142

H4H(X)P1000FC

10

460/3

10-4

8.63

151465142

H4H(X)P1000GC

10

575/3

10-4

8.63

151465142

H4H(X)P1500DC

15

208/3

8-4

9.50

151465022

H4H(X)P1500EC

15

230/3

8-4

9.50

151465022

H4H(X)P1500FC

15

460/3

8-4

9.50

151465022

H4H(X)P1500GC

15

575/3

10-4

9.50

151465022

MOTOR PARTS GROUP

H3H(X)P 

H4H(X)P

Summary of Contents for C4S(X)P Series

Page 1: ...03 557 01 23 20 Part 056255571 INSTALLATIONAND OPERATIONMANUAL SUBMERSIBLESOLIDSHANDLINGPUMP C4S X P H3H X P H4H X P S4M X P S4P X P S4HV X P S4MV X P Used in Hazardous Locations Class I Division I G...

Page 2: ...ENTS SECTION PAGE General Information 3 4 Pump Installation 5 Pump Operation Maintenance 6 7 Parts List 8 Hydraulic Ends Part List 9 Motor Parts Group 10 Impeller Parts List 10 11 Wiring Diagrams 12 W...

Page 3: ...l An improperly sized tank can cause the pump to cycle and lead to pump damage This may require a larger pressure tank than is normally used CALIFORNIA PROPOSITION 65 WARNING This product and related...

Page 4: ...nding temperature the starter in the panel breaks power to the pump Once the sensor resets the starter is automatically reset for FM for continued operation of the pump This circuitry is supplied in a...

Page 5: ...any other voltage TO RE WIRE THE PUMP FROM 230V TO 460V 3 PHASE Only a 230V pump from the factory is considered dual voltage a cord label clearly states the factory wound voltage 1 Remove all six 7 ca...

Page 6: ...le motors that are out of warranty can be serviced in the field by any reliable motor service shop Any pump that is in warranty must be returned to the factory for service or repaired at an authorized...

Page 7: ...ity 1 Discharge gate valve may be partially closed or partially clogged 2 Check valve may be partially clogged Raise level up and down to clear 3 Pump may be running in wrong direction Low speed pumps...

Page 8: ...78190103 SEAL PLATE S4P X P H3H X P H4H X P C4S X P 1 B6 07597A017 BOLT SEAL PLATE S4M X P S4MV X P S4HV X P 4 047560061 BOLT SEAL PLATE S4P X P H3H X P H4H X P C4S X P 4 Ref No Part No Part Descripti...

Page 9: ...21 005680021 005680021 005680191 D9 CHOPPER PLATE N A N A N A N A N A N A 153340002 D10 CHOPPER BLADE N A N A N A N A N A N A 153320002 D11 RETAINER PLATE N A N A N A N A N A N A 153330001 D12 SCREW C...

Page 10: ...5102 H3H X P500DC 5 208 3 10 4 7 50 151465102 H3H X P500EC 5 230 3 10 4 7 50 151465102 H3H X P500FC 5 460 3 10 4 7 50 151465102 H3H X P500GC 5 575 3 10 4 7 50 151465102 H3H X P750CC 7 5 230 1 8 4 8 00...

Page 11: ...C4S X P750DC 7 5 208 3 8 4 7 153310192 C4S X P750EC 7 5 230 3 8 4 7 153310192 C4S X P750FC 7 5 460 3 10 4 7 153310192 C4S X P750GC 7 5 575 3 10 4 7 153310192 C4S X P1000DC 10 208 3 8 4 7 153310192 C4S...

Page 12: ...CAN ONLY BE CONNECTED TO PANEL TERMINAL BLOCKS AS SHOWN ON SCHEMATIC INCORRECT CONNECTION CAN CAUSE DAMAGE TO PUMP AND OR PANEL COMPONENTS THREE PHASE OVERLOAD RELAY MUST BE CLASS 1O TRIP AMBIENT COMP...

Page 13: ...ll not apply a to defects or malfunctions resulting from failure to properly install operate or main tain the unit in accordance with the printed instructions provided b to failures resulting from abu...

Page 14: ...14 E 03 577 01 23 20 NOTES...

Page 15: ...15 E 03 577 01 23 20 NOTES...

Page 16: ...and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications wi...