STARTING UP
1. Start the device pressing
2. Introduce the nominal pump
current:
- Press and hold for 3
seconds.
- We view on the intermittent
screen the nominal current with
the ON led.
- Via the keys and
adjust the
nominal current indicated on the
pump plate. See Note 1.
- Press
to validate.
•
Press
+
for 5 seconds.
•
Use the keys
or
to modify
the values.
3. Introduce operating pressure:
- Press
for 2 seconds.
- We view start pressure
flashing and the
- START ON led.
- Via the keys
and
adjust
the start pressure from 0.5 to
7 bar.
- Press
to validate.
4. Introduce stop pressure:
- Press
for 3 seconds.
- We view on the screen the stop
•
Press
to validate and to move
to the next one.
pressure flashing and the STOP
ON led.
- Via the keys
and
adjust
the stopping pressure from 1
to 8 bar.
- Press
to validate.
5.
I device remains configured and
ready for use.
•
The sequence of parameters is
as follows:
Before starting up the device it is necessary to read the previous points, especially "Hydraulic System" and
"Electrical Installation".
DANGER
NOTE 1
BASIC PROGRAMMING MENU
it is very important to introduce exactly the nominal current on the pump specifications plate.
Basic operational start-up consists of:
•
Press
+
+
for 5 seconds.
•
Use the keys
or
to modify
the values.
•
Press
to validate and to move
to the next parameter.
•
The sequence of parameters is
as follows:
ADVANCED PROGRAMMING MENU
IT
TYPE
SYSTEM REACTION
DEFAULT
SETTING
1
BAR
P
It allows selection of the units in which
the pressure between bar and psi is displayed
bar
2
rc0
rc1
Rapid cycles alarm:
- rc0: deactivated.
- rc1: alarm activated, when it is detected, a delay is produced in start-up to protect the
pump.
- rc2: alarm activated, the pump stops when it is detected.
rc0
3
r.01
r. 99
If the rapid alarm cycles are activated in the previous point (rc1), we can select the
period of time between 3 consecutive start-ups, in seconds. We consider as rapid cycle
between 1" and 99".
5 seconds
4
Sb0
Sb1
Allows activation or deactivation of the display standby mode (Sb1) (Sb0) to save energy.
Sb0
Summary of Contents for DIGIPRESS
Page 10: ...IT ISTRUZIONI ORIGINALI 8 5 DIAGRAMMA A INDIVIDUALE GRUPPO SOLO SW2...
Page 12: ...10...
Page 20: ...USE AND MAINTENANCE MANUAL EN 18 5 DIAGRAM A INDIVIDUAL GROUP ONLY SW2...
Page 22: ...20...
Page 30: ...MANUEL D UTILISATION ET D ENTRETIEN FR 28 5 DIAGRAMME A INDIVIDUEL GROUPE UNIQUEMENT SW2...
Page 32: ...30...
Page 42: ...40...
Page 52: ...50...
Page 60: ...RECYZNY UZYWAINE I OBSLUGI PL 58 5 SCHEMAT A INDYWIDUALNY ZESP TYLKO SW2...
Page 62: ...60...
Page 70: ...MANUAL DE USO Y MANUTENCI N ES 68 5 DIAGRAMA A INDIVIDUAL GRUPO SOLO SW2 P P inicio 0 5 bar...
Page 76: ......
Page 77: ......