Indicators 01
Select Entry:
Here you can select the entry you want to want to use te set up an indicator. There are 16
entry’s that you can use.
Indicators:
Here you can create and set-up indicators that you can use on your screens or in your
program.
Mode:
The different mode’s you can use are:
- Weight
(filtered net weigher value that can react on multirange/interval)
- Fast Gross
- Fast Net
- Gross
- Net
- Tare
- Peak
- Valley
(unfiltered gross weigher value)
(unfiltered net weigher value)
(filtered gross weigher value)
(filtered net weigher value)
(tare value)
(highest reached weigher value can be reset by button peak reset)
(lowest reached weigher value can be reset by button valley reset)
- Weight x10
(filtered net weigher value shown with extra decimal that can react on
multirange/interval)
- Fast Gross x10
(unfiltered gross weigher value shown with extra decimal)
- Fast Net x10
(unfiltered net weigher value shown with extra
decimal)
- Gross x10
(filtered gross weigher value shown with extra decimal)
- Net x10
(filtered net weigher value shown with extra decimal)
- Tare x10
(tare value shown with extra decimal)
- Peak x10
(highest reached weigher value shown with extra decimal can be reset
by button peak reset)
- Valley x10
(lowest reached weigher value shown with extra decimal can be reset by
button valley reset)
- Sample
(direct value got from the loadcell(s))
Make sure each indicator is only used once!!!
Indicator: