FLEX 2100
22
Filter:
Overall:
The overall filter effects the signal which is used in the device.
The overall filter can be set at 0, -6db, -12db, -18db, -24db, -30,db, -36db -42 db and -50
db, where 0 means no effect and -50 is the strongest damping.
The sample rate has effect on the filter strength.
For fast dosing switch off this filter and use the Digital filter.
To prevent a loss of information or accuracy, don't set the overall filter higher than 24dB.
When no accuracy is needed, a higher filter setting is allowed to enable extreme filtering.
Filters are used because in an industrial environment there are always vibrations.
- From machines in the building
- Motors on the weighing device
- Mixers
- vibrators
- screws
- Etc.
- From the buildings itself.
The purpose of a filter is to get the most steady and reliable weighing signal
.
possible
Note:
be aware that filters are not a miracle. Good mechanics are very important
Filter settings 01
Before its possible to enter this menu, the indicator will ask for the “TAC” code. This “TAC”
code is shown in the right upper corner.
Digital:
This filter is better known as bessel filter. This filter only works with some sample rates.
The Digital filter can be set at None, Dynamic application and static application.
The Cutoff frequency can be set at 1,0Hz, 1,4Hz, 2,5Hz, 5,0Hz and 10Hz.