1020 Mono Filler
21
5
Inputs and outputs
The following inputs and outputs are used.
5.1
Inputs
Input Name
Description
Profibus
marker
EtherNet/IP
marker
1
Start/Stop Input must be high to run the program
969
433
2
Accept
tolerance
Input to accept the dosing when the end
value is out of tolerance.
970
434
3
Start
dosing or
start
release
Input to start dosing or release (depends
on the configuration parameters) when
the ready output is ON.
971
435
5.2
Outputs
Output Name
Description
1
Coarse
Output to enable coarse dosing.
The output turns on when the dosing starts and will turn off
when the setpoint minus the turnover value is reached.
2
Fine
Output to enable fine dosing.
The output turns on when the dosing starts and will turn off
when the setpoint minus the inflight value is reached.
The output also turns on if the end value is under the tolerance.
3
Ready
Output to enable the ready output. The output turns on when
dosing is not busy.
4
Release or
Alarm
When a release valve is selected in the configuration, this output
is used to activate the release valve.
When no release valve is selected in the configuration, this
output is used to activate the indicator alarm. This alarm can be
reset by switching off input 1.
Analog
out
Dosing speed
Dosing speed for coarse/fine filling will be available from 0,00%
to 100,00%