1020 Mono Filler
20
4.3
Live process parameters
When using the industrial protocol register functions, each parameter can be read using its
number.
Example: to read the value of low level, Use the function code 701 and value 1.
No. Name
Description
1
Setpoint
Get the setpoint value.
2
Turnover
Get the turnover value.
3
Subtotal
std.dev
Get the standard deviation of the subtotal.
4
Subtotal
average
Get the average value of the subtotal.
5
Subtotal
(weight) ok
Get the weight of the accepted products of the subtotal.
6
Subtotal count
ok
Get the number of accepted product of the subtotal.
7
Reserved
-
8
Reserved
-
9
Reserved
-
10 Total
Std.dev
Get the standard deviation of the total batch.
11 Total
average
Get the average value of the total batch.
12 Total (weight)
ok
Get the weight of the accepted products of the total batch.
13 Total count
ok
Get the number of accepted product of the total batch.
14 Reserved
-
15 Reserved
-
16 Reserved
-
17 Alibi number