Pelonis KCD25Y1 Instruction Manual Download Page 5

This appliance is designed to be highly efficient

n energy savings.

i

Follow these recommendations

for greater efficiency.

1) Select a thermostat setting that suits your

comfort needs and leave at that chosen setting.

2) The air filter is very effcient in removing airborne

particles. Keep the air filter clean at all times.

3) Use drapes, curtains or shades to keep direct

sunlight form penetrating and heating room, but

do not allow drapes or curtains to obstruct the

air flow around the unit.

4) Start your air conditioner before the outdoor air

becomes hot and uncomfortable. This avoids an

initial period of discomfort while the unit is

cooling off the room. Use of the automatic

start/stop programmable

feature can be a

major asset in this regard if utilized to the fullest

extent.

5) When outdoor temperatures are cool enough,

turn the air conditioner off and use the

on

or

This circulates

indoor air, providing some cooling comfort and

utilizes less electricity.

TIMER

FAN

MODE

HIGH, MED

LOW.

The exhaust/window kit must be installed at all

times when the unit is operating under the

mode.

There should be at least 11.8"(30 cm) clearance

between the unit and any other other objects or building

structure. The unit should be installed on a level

surface. The window kit does not have to be

installed during operation of the remaining three

modes. (Heating/Dehumidifying/Fan).

AIR

CONDITIONING

Energy-Saving Tips

Window Installation

Installation Accessories

Description

Quantity

Flexible exhaust hose with adapters

Window exhaust adapter

Adjustable window/patio door slider kit

Drain hose connector

SPECIAL NOTE:

Fig.1

..........3/set

stretches from 19 / " (50cm) up to

78 / " (200cm)

(flat mouth)...........1Pc

......2/set

from26 / " (67.5cm) up to

48 / "(203cm)

.........................1 Pc

continuous drain option (hose not included)

Exterior drain hose extension

(direct drain) is not included with this unit and can

be purchased through any local Hardware Store.

1

3

5

3

2

4

8

8

Electric Shock Hazard

To avoid the possibility of personal

injury, disconnect power to the unit

before installing or servicing.

To avoid installation/operation difficulties,

read these instructions thorughly.

4

Fig. 1 Installation Accessories

Drain Hose Connector

Window Exhaust

Adapter

Adapter

Adapter

Adjustable Window/Patio Door Slider Kit

26 / " - 48 /

5

3

8

8

Flexible Exhaust Hose

19 / - 78 /

1

3

2

4

"

CAUTION

!

!

Adjustable Window/Patio Door Slider Kit

26 / - 48 /

5

3

8

8

"

"

"

Summary of Contents for KCD25Y1

Page 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL Read Rules for Safe Operation and Instructions Carefully...

Page 2: ......

Page 3: ...leave this unit unattended in a space where people or animals who cannot react to a failed unit are located A failed unit can cause extreme overheating or death in such an enclosed unattended space CA...

Page 4: ...d or servicing Electrical Specifications Unit Specifications Power Consumption Cooling Capacity Heating Capacity Dehumidifying Capacity Noise Level Power Source Refrigerant Water Tank Capacity Unit We...

Page 5: ...r the mode There should be at least 11 8 30 cm clearance between the unit and any other other objects or building structure The unit should be installed on a level surface The window kit does not have...

Page 6: ...the cabinet otherwise the unit will not operate Fig 4 5 To turn the unit on press the key On Off Switch Water Tank Safety Feature FULL 8 BEEPS WATER FULL This unit is equipped with a fail safe switch...

Page 7: ...adjust forward Time of Day Clock Used to adjust backward Time of Day Clock settings 1min increments settings 1min increments Used to adjust forward Temperature Used to adjust backward Temperature set...

Page 8: ...clock program In the event this should happen you will be required to re set the clock program 1 Install the Fig 10 and the as depicted in Fig 2 2a 2b pg 5 2 Press the I O on off key pad to switch on...

Page 9: ...perature level The temperature has no effect on the fan operation Therefore the fan will operate continuously after the compressor has cycled off to maintain optimal temperature control 12 00 00 TIMER...

Page 10: ...cannot select a fan speed The fan motor operates at a pre set speed which registers as in the window 4 Condensed water will be accumulated in the water tank When the tank is full the unit will sound...

Page 11: ...nk when re locating your unit to a location room where continuous draining is not possible drain hose the internal drain hose and or leave Fig 19 Garden Hose not included Drain Hose Connector 10 Durin...

Page 12: ...the key to activate the automatic air swing oscillating feature the air swing symbol will appear in the window Fig 23 To deactivate the air swing feature press the key again 5 To adjust air flow direc...

Page 13: ...ection will be displayed in the window Each depression of the fan key will advance to a different speed 4 Press the key to activate the automatic air swing oscillating feature the air swing symbol wil...

Page 14: ...ridden and or canceled Any interruption to the electrical power supply of the unit automatically cancels erases all auto timed programs In the event this should happen you will be required to re set y...

Page 15: ...ime Fig 32a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is established the time will flash in the display w...

Page 16: ...he or key pad to select the desired start Fig 33a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is establishe...

Page 17: ...d to select the desired time Fig 32a Key pad will decrease the setting in 10 minute increments Key pad will decrease the setting in 10 minute increments When the desired time is established the time w...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...ull the filter out then up Fig 34 3 Dust Dirt clogged in the filter can be removed by vacuum cleaning the soiled areas 4 The filter can also be washed in lukewarm soapy water while rubbing it lightly...

Reviews: