Pelonis KCD25Y1 Instruction Manual Download Page 12

Heater Operating Instructions(For Heating/Cooling Models Only)

MODE

LCD

MODE

(Cool-Heat-Dry Fan).

FAN

(High-Low).

LCD

SWING

LCD

SWING

Horizontal Louver Blades

(excluding the top or bottom louver)

1) Press the

key until the word Heat is

displayed in the

window. Fig.20. Each

depression of the

key will advance to a

different mode setting

The

red indicator light will come on indicating the
"Heating "mode is operational (there may be a
slight delay of 5-10 seconds before the cycle
begins, this is normal).

2) Press the appropriate

or

key

to select a suitable temperature between

17 C (63 F) to 30 C (86 F). Fig.21.

3) Press the

key to select the desired fan

speed setting

Your selection will be

displayed in the

window. Each depression

of the fan key will alternate between the different
fan speed settings. Fig.22.

4) Press the

key to activate the automatic

air swing (oscillating) feature, (the "air swing"
symbol will appear in the

window). Fig.23.

To deactivate the air swing feature, press the

key again.

5) To adjust"air flow" direction, (up / down only )

adjust any one of the

and the

remaining louvers will automatically adjust to the
same position. Fig.24.

Heating stops automatically when the room
temperature reaches the desired setting .The "red"
indicator mode light will close. Heating will resume
when the room temperature falls below the
established temperature setting.

o

o

o

o

Fig. 20

Fig. 21

Fig. 22

Fig. 23

Fig. 24

SWING

SWING

SWING

OFF

OFF

OFF

ON

ON

ON

ON

MODE

MODE

MODE

MODE

TIMER

TIMER

TIMER

TIMER

FAN

FAN

FAN

I/O

I/O

I/O

I/O

CLOCK

CLOCK

CLOCK

12:00

12:00

12:00

12:00

00

HEAT

HEAT

HEAT

HEAT

HIGH

HIGH

HIGH

HIGH

Red Light

Heat Mode

Temperature

Fan Speed

Air Swing

Water Full

Cool/Heat/Dry

25 c

25 c

25 c

TIMER

TIMER

TIMER

TIMER

MODE

MODE

MODE

MODE

FAN SPEED

FAN SPEED

FAN SPEED

SWING

FAN SPEED

ON

ON

ON

ON

TEMP.

TEMP.

TEMP.

TEMP.

11

Summary of Contents for KCD25Y1

Page 1: ...PORTABLE AIR CONDITIONER INSTRUCTION MANUAL Read Rules for Safe Operation and Instructions Carefully...

Page 2: ......

Page 3: ...leave this unit unattended in a space where people or animals who cannot react to a failed unit are located A failed unit can cause extreme overheating or death in such an enclosed unattended space CA...

Page 4: ...d or servicing Electrical Specifications Unit Specifications Power Consumption Cooling Capacity Heating Capacity Dehumidifying Capacity Noise Level Power Source Refrigerant Water Tank Capacity Unit We...

Page 5: ...r the mode There should be at least 11 8 30 cm clearance between the unit and any other other objects or building structure The unit should be installed on a level surface The window kit does not have...

Page 6: ...the cabinet otherwise the unit will not operate Fig 4 5 To turn the unit on press the key On Off Switch Water Tank Safety Feature FULL 8 BEEPS WATER FULL This unit is equipped with a fail safe switch...

Page 7: ...adjust forward Time of Day Clock Used to adjust backward Time of Day Clock settings 1min increments settings 1min increments Used to adjust forward Temperature Used to adjust backward Temperature set...

Page 8: ...clock program In the event this should happen you will be required to re set the clock program 1 Install the Fig 10 and the as depicted in Fig 2 2a 2b pg 5 2 Press the I O on off key pad to switch on...

Page 9: ...perature level The temperature has no effect on the fan operation Therefore the fan will operate continuously after the compressor has cycled off to maintain optimal temperature control 12 00 00 TIMER...

Page 10: ...cannot select a fan speed The fan motor operates at a pre set speed which registers as in the window 4 Condensed water will be accumulated in the water tank When the tank is full the unit will sound...

Page 11: ...nk when re locating your unit to a location room where continuous draining is not possible drain hose the internal drain hose and or leave Fig 19 Garden Hose not included Drain Hose Connector 10 Durin...

Page 12: ...the key to activate the automatic air swing oscillating feature the air swing symbol will appear in the window Fig 23 To deactivate the air swing feature press the key again 5 To adjust air flow direc...

Page 13: ...ection will be displayed in the window Each depression of the fan key will advance to a different speed 4 Press the key to activate the automatic air swing oscillating feature the air swing symbol wil...

Page 14: ...ridden and or canceled Any interruption to the electrical power supply of the unit automatically cancels erases all auto timed programs In the event this should happen you will be required to re set y...

Page 15: ...ime Fig 32a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is established the time will flash in the display w...

Page 16: ...he or key pad to select the desired start Fig 33a Key pad will decrease the Setting in 10 minute increments Keypad will increase the Setting in 10 minute increments When the desired time is establishe...

Page 17: ...d to select the desired time Fig 32a Key pad will decrease the setting in 10 minute increments Key pad will decrease the setting in 10 minute increments When the desired time is established the time w...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ...ull the filter out then up Fig 34 3 Dust Dirt clogged in the filter can be removed by vacuum cleaning the soiled areas 4 The filter can also be washed in lukewarm soapy water while rubbing it lightly...