7. INCIDENTS AND TROUBLESHOOTING
Important
For any problems concerning the battery, refer to the manual that comes with the battery.
PELLENC recom-
mends contacting an authorised PELLENC dealer in all cases of breakdown.
7.1. TROUBLESHOOTING SYMPTOMS OF THE HELION 3 ELECTRIC HEDGE TRIMMER
Symptom
Check
Probable cause
Solutions
Battery discharged
Charge the battery
Battery defective
Change the battery
Check the power cable
The LEDs are off
Wrong connection
with the battery
Check the connections (tool and
battery) Clean them with com-
pressed air if necessary. Check
that all switches are active. Re-
peat the operation if necessary.
Safety at start-up/
Standby (Delay > 5min)
Double-click the trigger of
the rear handle and pull the
trigger of the front handle.
The On/Off switch-
es are defective
Unplug the power cable and
plug in again. Restart the battery
Cutting blade blocked
Clean and lubricate the blade
The LEDs are lit
Internal loose connection
Contact your autho-
rised PELLENC dealer
The hedge trim-
mer does not work
LEDs flashing
inside/outside
Safety when
switching on
Release the front handle
The LEDs light-
up intermittently
Damaged power cords
Change the power cable
Blade is clogged
Clean and lubricate the blade
The hedge trimmer
works intermittently
The LEDs are always on
The On/Off switch-
es are defective
Contact your autho-
rised PELLENC dealer