GRASS STRIMMER EXCELION ALPHA
53_144013_C
7. INCIDENTS AND TROUBLESHOOTING
7.1. TABLE OF INCIDENTS AND BREAKDOWNS - TROUBLESHOOTING
LED status
Incident /
breakdown of the battery of the tool
handle
Probable cause
Checks
Solutions
Repairer
0
Off
Battery is off
Battery switch
Press the
button on
the battery
User
Battery
Check that the bat-
tery is not com-
pletely discharged
Recharge
the battery
User
Off
Electronic cir-
cuit board
At an autho-
rised PEL-
LENC distributor
Change the
circuit board
Pellenc au-
thorised
distributor
Trigger no
longer functions
At an autho-
rised PEL-
LENC distributor
Change
the trigger
or sensor
PELLENC
authorised
distributor
The tool
does not start
I
On
Electronic cir-
cuit board
At an autho-
rised PEL-
LENC distributor
Change the
circuit board
Authorised
PELLENC
distributor
User
Damaged
cutting head
Check there is
no deformation
Change the
cutting head
Pellenc au-
thorised
distributor
Motor shaft
damaged
Check the condi-
tion of the shaft
(no distortion)
Change the
motor shaft
Authorised
PELLENC
distributor
Check that you
are in speed 3
See Sec-
User
Strimmer wire
not cut to length
Check that the
wire cutting
plate is fitted
Refit the
strimmer wire
cutter plate
User
Strimmer
wire too long
Check that the
protective cas-
ing is fitted
Fit the pro-
tective cas-
User
The cutting
head makes
an abnormal
noise or vi-
brates a lot
I
On
Strimmer wire
badly wound in
the cutting head
Check the wind-
ing of the strim-
mer wire in the
cutting head.
See Sec-
User
34