BACKPACK BLOWER AIRION BP
57_148610-A
Diagnostics
display codes
Designation
Probable cause
Checks
Solutions
Repairer
Fault 1
Trigger fault
Trigger no
longer works
Authorised PEL-
LENC distributor
Change
the trigger
Authorised PEL-
LENC distributor
Fault 2
Menu button fault
The button no
longer works
Authorised PEL-
LENC distributor
Change the
menu button
Authorised PEL-
LENC distributor
Fault 3
Selector fault
The selector
does not work
Authorised PEL-
LENC distributor
Change
the selector
Authorised PEL-
LENC distributor
User
Allow the tool
to cool down
User
Fault 4
Temperature fault
Tool tempera-
ture too high
Authorised PEL-
LENC distributor
Tool check
Authorised PEL-
LENC distributor
Fault 5
Communi-
cation fault
Communication
between the tool
and the battery
is interrupted
Authorised PEL-
LENC distributor
Check cables
and connectors
Authorised PEL-
LENC distributor
The battery con-
nector on the tool
no longer works
Authorised PEL-
LENC distributor
Check cables,
connectors
and battery
Authorised PEL-
LENC distributor
Fault 6
Battery fault
Non compat-
ible battery
User
Use a com-
patible battery
User
Important
Never attempt to dismantle the tool, under penalty of cancellation of the warranty. Contact your authorised
repair person.
44