3. Feed the positive and cathode cables into corresponding lock screws.
4. Put the metal positive and cathode terminals into positive cable and cathode
cable whose insulated enclosure has been stripped, and crimp them tightly
with a wire crimper. Make sure that the withdrawal force of the pressed
cable is bigger than 400N.
5. Plug the pressed positive and cathode cables into relevant insulated
enclosure, a“click” should be heard or felt when the contact cable assembly
is seated correctly.
6. Fasten the lock screws on positive and negative connectors into respondent
insulated enclosure and make them tight.
7. Connect the positive and cathode connectors into positive and negative
DC input terminals of the inverter, a“click” should be heard or felt when the
contact cable assembly is seated correctly.
Connection Port
Connection Port
NOTICE
•
Before inserting the connector into the DC input terminal
of the inverter, please make sure that the DC switch of the
inverter is OFF.