background image

493oA_Rev06_061109.pdf

GB - 2

126114-02

Paul Hochköpper GmbH & Co. KG • Postfach 1727 • D-58467 Lüdenscheid • Tel.: (02351)185-0 • Fax: (02351)27666 • e-mail: [email protected] • Internet: www.peha.de

Elektronik

Elektronik

Elektronik

Elektronik

Elektronik

10. Functions for the PEHA

single-switch and Easywave
wireless attachment

10.1 Function selector switch - position 1

"Tactile switch"

10.2 Function selector switch - position 2

"Momentary contact"

10.3 Function selector switch - position 3

"Stairwell switch"

10.4 Function selector switch - position 4

"Time switch, short-term"

10.5 Function selector switch - position 5

"Time switch, long-term"

10.6 Function selector switch - position 6

"Time switch, programmable"

Programming a new switching period:

a) The light is off

After pressing the button for about 3 s the light will switch on;
the new time period to be programmed begins to accumulate.
For switches with an LED, the LED will begin to blink.

b) The light is on

After pressing the button for about 3 s the light will switch off
and the expired time will be stored.
For a switch with LED, the LED will cease to blink.

Maximum programmable time..............................17 hours
0 to 2 minutes........................................exact to the second
2 minutes to 2 hours...............................exact to the minute
2 hours to 17 hours....................................exact to the hour

11. PEHA double-switch

functions

11.1 Function selector switch - position 1

"Tactile switch"

12. Functions of the PEHA Infrared

attachment and remote control

Only one remote control unit can be used for
a given FM module with infrared attachment.
When the remote control unit is used for the first time its 

basic

level 

(level 0) and 

Group 1

 are active.

To use another level (1 ... 6) in the remote control unit, the infrared
address for the remote control unit must be stored in the FM
module. This is done by holding down the attachment's button

continuously

. Once the attachment's LED begins to blink, the

desired level button (1 ... 6) must be pressed and thereafter one
of the function buttons

 "On/Off - UP 

U

U

U

U

U

 - Down 

V

V

V

V

V

"

.

The LED will stop blinking when a correct IR telegram has been
received; thus storing the IR address in a non-volatile memory.
After this procedure has been completed the button on the
attachment can be released.

12.1 Function selector switch - position 1

"Tactile switch"

12.2 Function selector switch - position 2

"Momentary contact"

12.3 Function selector switch - position 3

"Time switch, short-term"

12.4 Function selector switch - position 4

"Time switch, long-term"

Tactile attachment,  
remote station 

Function 

Press button briefly/release   Switch on/off 
 

 

Function pot.

 (see Point 9)

 

Potentiometer function 1  

Tactile attachment,  
remote station  

Function 

Press button 

Switch on 

Release button 

Switch off 

 

Function pot.

 (see Point 9) 

Potentiometer function 1

Tactile attachment, 
remote station 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to restart period! 

 

Function pot. 

(s. Point 9)  Potentiometer function 2 

Function LED 

(attachment) 

Orientation light!  
No premature switch-off 
possible! 

Tactile attachment, 
remote station 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to switch off! 

 

Function pot. 

(s. Point 9)  Potentiometer function 2 

Function LED 

(attachment) 

Orientation light! Premature 
switch-off possible! 

Tactile attachment, 
remote station 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to switch off! 

 

Function pot. 

(s. Point 9)  Potentiometer function 3 

Function LED 

(attachment) 

Orientation light! Premature 
switch-off possible! 

Tactile attachment, 
remote station 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to switch off! 

 

Function LED 

(attachment) 

Orientation light! Premature 
switch-off possible! 

Remote station 

Function 

Press button briefly then release it  Switch on/off 
 

Tactile attachment 

Function 

Press the left button briefly 

Switch off 

Press the right button briefly 

Switch on 

IR cover, remote station 

Function 

Press button briefly then release it  Switch on/off 
 

Remote control unit 

Function 

On/Off - UP 

U

- Down 

V

  

press briefly 

Switch on/off 

 

LED function 

(attachment) 

LED lights upon receipt of an  
IR telegram.  
Premature switch-off possible! 

IR cover, remote station 

Function 

Press button  

Switch on 

Release button 

Switch off 

 

Remote control unit 

Function 

On/Off - UP 

U

- Down 

V

 

press 

 

Switch on 

On/Off - UP 

U

- Down 

V

 release  Switch off 

 

LED function 

(attachment) 

LED lights upon receipt  
of an IR telegram 

IR cover, remote station  
or remote control 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to switch off! 

 

Function pot. 

(see Point 9)

 

Potentiometer function 2  

Function LED 

(attachment) 

LED lights upon receipt 
of an IR telegram! 

IR cover, remote station  
or remote control 

Function 

Press button briefly  
then release it 

Switch on for the preset 
period or to switch off! 

 

Function pot. 

(see Point 9)

 

Potentiometer function 3  

Function LED 

(attachment) 

LED lights upon receipt 
of an IR telegram! 

13. PEHA motion sensor

functions

Setting switched-on time
and the ambient-light threshold:

The setting for switched-on time is made with the motion sensor's
adjustable potentiometer for switch-on period. The setting for
ambient-light threshold is made with the motion sensor's
adjustable potentiometer for ambient-light value.

13.1 Function selector switch - position 1

"Motion sensor"

In the event that both timers are running (switched-on time
in both the motion sensor and its remote station) the relay
unit will be switched off by the timer which expires last.

13.2 Function selector switch - position 2

"Multi-master motion sensor"

Multi-Master:

Another local motion sensor will also respond when the ambient-
light value has not been reached by the switched-on light.

Caution:

A minimum load of at least 25 W must be maintained!

Operating multiple units in parallel:

The setting for switched-on time is made with the given motion
sensor's adjustable potentiometer for switch-on period. The setting
for ambient-light threshold is made with the given motion sensor's
adjustable potentiometer for ambient-light value.

Remote station input:

The remote station input controls the switched line.

13.3 Function selector switch - position 3

"Motion sensor without continuous light button"

The button for continuous light will be deactivated after about 1 min.

Functions of the remote station and pot.:

See 13.1, Function selector switch - position 1

Remote station 

Function 

Press button briefly 
then release it 

Switch-on for the preset 
illumination period   

 

Illumination period 

(rem. station)

 

1 ... 60 minutes 

Potentiometer

 (see Point 9)

 

Potentiometer function 4  

Reviews: