background image

 

   

Page 8 

USE AND MAINTENANCE MANUAL 

Rev. 02-18 

PLUS

100

 AB 

 

WARRANTY TERMS 

 
 

PLUS100  AB 

series  products  are  covered  by  a  24-months  warranty  against  all 

manufacturing defects as from the date indicated on the product ID code. 

 

In case of defect the product must be appropriately packaged and sent to our production 
plant or to any authorized Service Center with the prior request of the Return Authorization 
Number. 

 

Customers  are  entitled  to  have  defective  products  repaired,  spare  parts  and  labour 
included. The costs and the risks of transport are at the total charge of the Customer. 
Any warranty action does not extend or renew its expiration. 

 

The Warranty does not cover: 

  Damages resulting from tampering, impact or improper installation of the product and 

its accessories. 

  Installation,  use  or  maintenance  that  does  not  comply  with  the  instructions  provided 

with the product. 

  Repair work carried out by unauthorized personnel. 

 

Damage due to natural phenomena such as lightning, natural disasters, etc… 

 

In all these cases the costs for repair will be charged to the customer. 

 

The  intervention  service  in  warranty  can  be  refused  when  the  equipment  is  modified  or 
transformed. 

 

Under  no  circumstances 

Pego  S.r.l.

  will  be  liable  for  any  loss  of  data  and  information, 

costs of goods or substitute services, damage to property, people or animals, loss of sales 
or  earnings,  business  interruption,  any  direct,  indirect,  incidental,  consequential, 
damaging,  punitive,  special  or  consequential  damages,  in  any  way  whatsoever  caused, 
whether they are contractual, extra contractual or due to negligence or other liability arising 
from the use of the product or its installation. 

 

Malfunction  caused  by  tampering,  bumps,  inadequate  installation  automatically  declines 
the  warranty.  It  is  compulsory  to  observe  all  the  instructions  in  this  manual  and  the 
operating conditions of the product. 

 

Pego S.r.l.

 disclaims any liability for possible inaccuracies contained in this manual if due 

to errors in printing or transcription. 

 

Pego S.r.l.

 reserves the right to make changes to its products which it deems necessary 

or useful without affecting its essential characteristics. 

 

Each new release of the Pego product user manual replaces all the previous ones. 

 

As far as not expressly indicated, is applicable the Law and in particular the art. 1512 C.C. 
(Italian Civil Code). 

 

For any controversy is elected and recognized by the parties the jurisdiction of the Court of 
Rovigo.         

4.2 

CHAP. 4 

– Technical characteristics 

Summary of Contents for PLUS100 AB

Page 1: ...PLUS100 AB Use and maintenance manual READ AND KEEP REV 02 18 ENG ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS...

Page 2: ...tures Page 12 5 5 Key to symbols Page 12 5 6 Setting and displaying the set points Page 13 5 7 Programming the type of work Page 17 5 8 Level 1 programming Page 18 5 9 List of Level 1 variables Page 1...

Page 3: ...nts on a refrigeration unit The board allows the user to control and power the main refrigeration system components such as the compressor evaporator fans defrosting elements and room light There is a...

Page 4: ...ERALL DIMENSIONS IDENTIFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code of the electrical board Serial...

Page 5: ...nimise the length of connector wires so that wiring does not twist into a spiral shape as this could have negative effects on the electronics 5 Fit a general protection fuse upstream from the electron...

Page 6: ...evaporator temperature System control activation deactivation System warnings sensor error min max temperature alarms compressor safety device Evaporator fan control Automatic manual defrost control s...

Page 7: ...sion 0 5 C Read range 45 45 Output characteristics max applicable load 230VAC Compressor non powered contact 1500 W AC3 Elements non powered contact 1500 W AC1 Fans non powered contact 500 W AC3 Room...

Page 8: ...pment is modified or transformed Under no circumstances Pego S r l will be liable for any loss of data and information costs of goods or substitute services damage to property people or animals loss o...

Page 9: ...onths also remain lit 2 Indicator warning LEDs a Cold cooling in progress b Quick freezing rapid freezing in progress c Temperature freezing cooling freezing by temperature PR1 PR2 PR3 d Time freezing...

Page 10: ...r a few seconds the cooling cycle starts 2 UP MUTE BUZZER ALARM key if pressed for 5 seconds together with key 1 recorded alarms are displayed 3 STAND BY key system shuts down room temperature light f...

Page 11: ...rent month see setting on parameter tEu on 1st level programming parameters during programming for values greater than 45 C the word HOT is displayed 3 Time date time parameter values 4 Programming co...

Page 12: ...Level 2 programming directly from Level 1 you must exit the programming mode first KEY TO SYMBOLS For purposes of practicality the following symbols are used the UP key is used to increase values and...

Page 13: ...ure based cooling Program for product cooling by positive temperature Cooling ends when the core of the product reaches temperature At1 A maximum safety time is set on parameter Ab1 When cooling is ov...

Page 14: ...ing the control automatically goes to storage mode as per the ST3 setting ST3 also has the function of controlling the compressor during cooling the compressor stops if ambient temperature reaches ST3...

Page 15: ...hen maximum time Ab5 has expired When freezing is over the controller automatically goes to storage mode with the ST5 setting The compressor works continuously VARIABLES MEANING VALUES DEFAULT ST4 Sto...

Page 16: ...freezing the control automatically goes to storage mode as per setting ST6 ST6 also has the function of regulating the compressor during cooling the compressor stops if ambient temperature reaches ST6...

Page 17: ...ease the and keys 3 Select the variable to be modified using the or key 4 When the variable has been selected it is possible to display the setting by pressing SET to modify the setting by pressing th...

Page 18: ...defrost LED on the front of the panel flashes 0 30 min 0 min F5 Fan pause after defrost minutes Allows fans to be kept at standstill for a time F5 after dripping This time is counted from the end of d...

Page 19: ...eys and the LIGHT key simultaneously for a few seconds When the first programming variable appears the system automatically goes to stand by 1 Select the variable to be modified by pressing the UP and...

Page 20: ...he remote defrost contact trips or when time d3 expires 0 evaporator sensor present 1 evaporator sensor absent 0 dE1 Product sensor presence piercing temperature probe With dE1 1 it is possible to dis...

Page 21: ...ure value read by the evaporator sensor is higher than this value 45 45 C 45 C tA NO NC alarm relay switching 0 activates when alarm is on 1 deactivates when alarm is on 1 rA Control relay door anti f...

Page 22: ...using the up down keys Start the selected program by pressing key 1 for a few seconds It is also possible to start a program starting from stand by mode To confirm the start of a cycle the warning in...

Page 23: ...defrost cycle in inversion mode The compressor relay and defrost relay are activated throughout the defrost phase To ensure proper control of the system the installer must use the defrost output this...

Page 24: ...h back on E5 Data write alarm The controller is not saving data correctly Contact technical assistance service E6 Flat battery alarm The controller will function for at least another 20 days subsequen...

Page 25: ...ts If problem persists contact technical assistance service Temperature shown on display is flashing Minimum or maximum temperature alarm The temperature inside the cold room has exceeded the min or m...

Page 26: ...C 2014 30 EU LA CONFORMITA PRESCRITTA DALLA DIRETTIVA E GARANTITA DALL ADEMPIMENTO A TUTTI GLI EFFETTI DELLE SEGUENTI NORME THE CONFORMITY REQUIRED BY THE DIRECTIVE IS GUARANTEED BY THE FULFILLMENT TO...

Page 27: ...od 7 8 Fans 31 32 NTC 10K evaporator 5 6 Defrost 3 4 Compressor Digital inputs 41 50 Compressor protection TeleNET section 42 50 Switch door 39 A line or clamp 3 2TWRS485 43 50 Remote end defrost 40 B...

Page 28: ...tina 6 b 45030 Occhiobello ROVIGO ITALY Tel 39 0425 762906 Fax 39 0425 762905 e mail info pego it www pego it AFTER SALES ASSISTANCE CENTRE Tel 39 0425 762906 e mail tecnico pego it Distributor PEGO s...

Reviews: