USE AND MAINTENANCE MANUAL 

Rev. 02-18 

PLUS

100

 AB 

 

LEVEL 1 PROGRAMMING (User level) 

 
 
To gain access to the Level 1 configuration menu proceed as follows: 

1

. Press the 

(

and 

(

)

 keys simultaneously and keep them pressed for a few seconds 

until the first programming variable appears on the display. 

2

. Release the 

(

and 

(

)

 keys. 

3

. Select the variable to be modified using the 

(

or 

(

key. 

4

. When the variable has been selected it is possible: 

• to display the setting by pressing SET. 

• to modify the setting by pressing the SET key and the 

(

or 

(

)

 keys. 

When  configuration  values  have  been  set  you  can  exit  the  menu  by  pressing  the 

(

and 

(

)

 keys simultaneously for a few seconds until the room temperature reappears. 

5

. The new settings are saved automatically when you exit the configuration menu. 

 
 
 

CHAP. 5 

– Parameter programming 

5.8 

Summary of Contents for PLUS100 AB

Page 1: ...PLUS100 AB Use and maintenance manual READ AND KEEP REV 02 18 ENG ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS...

Page 2: ...tures Page 12 5 5 Key to symbols Page 12 5 6 Setting and displaying the set points Page 13 5 7 Programming the type of work Page 17 5 8 Level 1 programming Page 18 5 9 List of Level 1 variables Page 1...

Page 3: ...nts on a refrigeration unit The board allows the user to control and power the main refrigeration system components such as the compressor evaporator fans defrosting elements and room light There is a...

Page 4: ...ERALL DIMENSIONS IDENTIFICATION DATA The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer Code of the electrical board Serial...

Page 5: ...nimise the length of connector wires so that wiring does not twist into a spiral shape as this could have negative effects on the electronics 5 Fit a general protection fuse upstream from the electron...

Page 6: ...evaporator temperature System control activation deactivation System warnings sensor error min max temperature alarms compressor safety device Evaporator fan control Automatic manual defrost control s...

Page 7: ...sion 0 5 C Read range 45 45 Output characteristics max applicable load 230VAC Compressor non powered contact 1500 W AC3 Elements non powered contact 1500 W AC1 Fans non powered contact 500 W AC3 Room...

Page 8: ...pment is modified or transformed Under no circumstances Pego S r l will be liable for any loss of data and information costs of goods or substitute services damage to property people or animals loss o...

Page 9: ...onths also remain lit 2 Indicator warning LEDs a Cold cooling in progress b Quick freezing rapid freezing in progress c Temperature freezing cooling freezing by temperature PR1 PR2 PR3 d Time freezing...

Page 10: ...r a few seconds the cooling cycle starts 2 UP MUTE BUZZER ALARM key if pressed for 5 seconds together with key 1 recorded alarms are displayed 3 STAND BY key system shuts down room temperature light f...

Page 11: ...rent month see setting on parameter tEu on 1st level programming parameters during programming for values greater than 45 C the word HOT is displayed 3 Time date time parameter values 4 Programming co...

Page 12: ...Level 2 programming directly from Level 1 you must exit the programming mode first KEY TO SYMBOLS For purposes of practicality the following symbols are used the UP key is used to increase values and...

Page 13: ...ure based cooling Program for product cooling by positive temperature Cooling ends when the core of the product reaches temperature At1 A maximum safety time is set on parameter Ab1 When cooling is ov...

Page 14: ...ing the control automatically goes to storage mode as per the ST3 setting ST3 also has the function of controlling the compressor during cooling the compressor stops if ambient temperature reaches ST3...

Page 15: ...hen maximum time Ab5 has expired When freezing is over the controller automatically goes to storage mode with the ST5 setting The compressor works continuously VARIABLES MEANING VALUES DEFAULT ST4 Sto...

Page 16: ...freezing the control automatically goes to storage mode as per setting ST6 ST6 also has the function of regulating the compressor during cooling the compressor stops if ambient temperature reaches ST6...

Page 17: ...ease the and keys 3 Select the variable to be modified using the or key 4 When the variable has been selected it is possible to display the setting by pressing SET to modify the setting by pressing th...

Page 18: ...defrost LED on the front of the panel flashes 0 30 min 0 min F5 Fan pause after defrost minutes Allows fans to be kept at standstill for a time F5 after dripping This time is counted from the end of d...

Page 19: ...eys and the LIGHT key simultaneously for a few seconds When the first programming variable appears the system automatically goes to stand by 1 Select the variable to be modified by pressing the UP and...

Page 20: ...he remote defrost contact trips or when time d3 expires 0 evaporator sensor present 1 evaporator sensor absent 0 dE1 Product sensor presence piercing temperature probe With dE1 1 it is possible to dis...

Page 21: ...ure value read by the evaporator sensor is higher than this value 45 45 C 45 C tA NO NC alarm relay switching 0 activates when alarm is on 1 deactivates when alarm is on 1 rA Control relay door anti f...

Page 22: ...using the up down keys Start the selected program by pressing key 1 for a few seconds It is also possible to start a program starting from stand by mode To confirm the start of a cycle the warning in...

Page 23: ...defrost cycle in inversion mode The compressor relay and defrost relay are activated throughout the defrost phase To ensure proper control of the system the installer must use the defrost output this...

Page 24: ...h back on E5 Data write alarm The controller is not saving data correctly Contact technical assistance service E6 Flat battery alarm The controller will function for at least another 20 days subsequen...

Page 25: ...ts If problem persists contact technical assistance service Temperature shown on display is flashing Minimum or maximum temperature alarm The temperature inside the cold room has exceeded the min or m...

Page 26: ...C 2014 30 EU LA CONFORMITA PRESCRITTA DALLA DIRETTIVA E GARANTITA DALL ADEMPIMENTO A TUTTI GLI EFFETTI DELLE SEGUENTI NORME THE CONFORMITY REQUIRED BY THE DIRECTIVE IS GUARANTEED BY THE FULFILLMENT TO...

Page 27: ...od 7 8 Fans 31 32 NTC 10K evaporator 5 6 Defrost 3 4 Compressor Digital inputs 41 50 Compressor protection TeleNET section 42 50 Switch door 39 A line or clamp 3 2TWRS485 43 50 Remote end defrost 40 B...

Page 28: ...tina 6 b 45030 Occhiobello ROVIGO ITALY Tel 39 0425 762906 Fax 39 0425 762905 e mail info pego it www pego it AFTER SALES ASSISTANCE CENTRE Tel 39 0425 762906 e mail tecnico pego it Distributor PEGO s...

Reviews: