Expert
nano LINE
200NANO1LT**
Thermorégulateur électronique / Electronic thermostat
Manuel d’utilisation et d’entretien / Use and maintenance
manual
Manuale d’uso e manutenzione / Use and maintenance manual
PEGO S.r.l.
Via Piacentina, 6/b - 45030 - ROVIGO
Tel : 0425 762906 - Fax: 0425 762905
www.pego.it - e-mail: [email protected]
200NAN1LT_01-18_FRA # Rev.01-18 # 22/02/2018
Manuale d’uso e manutenzione / Use and maintenance manual
Push to
remove
Pannel
DESCRIPTION
The Expert nano model 200NANO1LT is an electronic regulator
operating with microprocessor designed to control static
refrigeration units operating at normal temperature with off-
cycle defrosting (to stop compressor). It is fitted with one
analogue input for NTC or PTC temperature probes and one
relay for the control of the compressor. The regulator can be
also configured for heat or alarm applications.
PRINCIPAL CHARACTERISTICS
Can be configured for hot or cold or alarm applications.
Off-cycle defrosting can be set on the basis of frequency or
duration.
Key operated manual START/STOP defrosting.
Key operated ON/OFF.
Display/adjustment of temperature with decimal point.
Flat front surface for easy cleaning and keys of ample dimensions
which can be customised with various colours (on request).
3-Digit LED display with sign, decimal point and system status icon.
PEGO programming philosophy guaranteeing immediate start-up.
IP65 front protection. Two-fold fastening option: clips / screws.
Relay capacity and power depending on model.
FRONT VIEW OF DEVICE
COMBINED ACTIVATION OF KEYS AND THEIR FUNCTIONS
FUNCTION / KEY COMBINATION
SETTINGS PROGRAMMING /
(Set +
o
)
Press the SET key to view the current SETPOINT value
(temperature).
Keeping the SET key down and pressing either the (
) or (
)
key, the SETPOINT value can be changed.
Release the SET key to return to view the room temperature;
the changes made will be automatically saved.
LEVEL 1 PROGRAMMING /
(
+
)
Press the UP and DOWN keys simultaneously for over 3 sec. to
access the Level 1 programming menu. The system leaves the
menu after 30 seconds.
LEVEL 2 PROGRAMMING
/ (
+
+ Stand-by)
Press the UP, DOWN and STAND-BY keys simultaneously for
over 3 sec. to access the Level 1 programming menu. When the
menu is accessed the system is placed in Stand-By mode.
EXIT PROGRAMMING MENUS /
(
+
)
Pressing the UP and DOWN buttons simultaneously in any
programming menu for over 3 sec. causes the system to save
the settings entered and leave that menu.
E N G L I S H
Power voltage
Model 200NANO1LT01
230 V
~
+10/-15% 50/60Hz
Model 200NANO1LT02
Model 200NANO1LT11
12V
~
+10/-15% 50/60Hz
12Vdc +10/-15% class 2
Absorbed power
3 VA Max
Environment conditions
Operating temperature
-5T55°C - humidity < 90% Rel. Hum. Not
condensing
Storage temperature
-20T70°C - humidity < 90% Rel. Hum. Not
condensing
Unsuitable operating
environments
Environments with strong vibrations or
impacts; aggressive, polluted or corrosive
atmospheres, exposure to direct solar
radiation, explosive atmospheres or
flammable gas.
General characteristics
Display
3-Digit with sign, decimal point and 9 LED
status indicators
Resolution
0,1 °C
Probe precision (electronic) ± 0,5 °C
Reading range
-45T99 °C
Model 200NANO1LT01
Model 200NANO1LT11
Fixed screw clamps with cross-section from
0.2 to 2.5mm
2
Model 200NANO1LT02
Removable, screw clamps for cables with
c/section 0.2 to 2.5mm
2
Software class: A / Parameters saved on non-volatile memory
(EEPROM)
Input characteristics
Analogue inputs
1 Input for NTC probe(10K Ώ 1% at 25°C)
Or
1 Input for PTC probe(KTY83-121)
Output characteristics Compressor relay (DO1)
Model 200NANO1LT01
Model 200NANO1LT11
Model 200NANO1LT02
N.O. 16(6)A / 250V
~
Dimensional, insulation and mechanical characteristics
Dimensions
93x37x65mm Depth 59mm
Drill hole template
71x29mm (+0,2/-0,1mm)
Front protection rating
IP65 with front board installation
Installation
In front of board by means of rear fastening
clips or or two front screws
Casing
Plastic PC+ABS UL94 V-0 body, PC
transparent front, Key panel PC or PC+ABS
Insulation type
Class II
Conformity with EU low voltage directives, electromagnetic compatibility
and EC mark
Conforms to following EU Directives :
Directives 2014/30/UE , 2014/35/UE
Conforms to following harmonised standards:
EN60730-1:2016, EN60730-2-9:2010, EN61000-6-1:2007, EN61000-6-3:2007
DRILL HOLE TEMPLATE (mm)
TECHNICAL DATA
KEY FUNCTIONS
Key
FUNCTION
UP KEY
Increases values / Scrolls parameters in ascending
order. Acknowledges an alarm.
DOWN KEY
Decreases values / Scrolls parameters in descending
order.
If pressed for over 3 seconds activates manual
defrosting.
Terminates defrosting if pressed for over 3 seconds
during the defrosting process.
Stand
by
STAND-BY KEY
If pressed for over 1 seconds alternates the Stand-By
with normal mode and vice versa. In Stand-By mode
the system stops and the display signals OFF and the
temperature alternating.
SET KEY
Displays the set point.
Allows the set point to be entered when pressed in
combination with the DOWN or UP keys.
STATUS ICON
ICON
MEANING
COLD FUNCTION ICON
(icon activated with mOd=0/2)
Led OFF = Cold function OFF
Led ON = Cold function ON
Flashing Led = Cold function ON waiting for C1 delay
HOT FUNCTION ICON
(icon activated with mOd=1/3)
Led OFF = Hot function OFF
Led ON = Hot function ON
DEFROSTING ICON
(icon activated with mOd=0/2)
Led OFF = Defrosting OFF
Led ON = Defrosting ON
ALARM ICON
Led OFF = No alarm present
Led ON = Indicates temperature alarm intervention
with remedy (HACCP alarm).
Flashing Led = Alarm present
FASTENING TO PANEL BY MEANS OF TWO BACK CLIPS
FASTENING TO PANEL BY MEANS OF TWO FRONT SCREW
Screw 2,9x9,5mm
Screw 2,9x9,5mm
DIMENSIONS (mm)
Distance between hole centres: 77mm