background image

 

 

Expert 

nano LINE

 

200NANO1LT**

   

Thermorégulateur électronique / Electronic thermostat 

Manuel d’utilisation et d’entretien / Use and maintenance 
manual 

 

Manuale d’uso e manutenzione / Use and maintenance manual

 

PEGO S.r.l. 

Via Piacentina, 6/b - 45030 -  ROVIGO 

Tel : 0425 762906 - Fax: 0425 762905 

www.pego.it   -  e-mail: [email protected] 

 

200NAN1LT_01-18_FRA  #  Rev.01-18  #  22/02/2018

 

 

Manuale d’uso e manutenzione / Use and maintenance manual

 

Push to 

remove

 

Pannel

 

 

 

 
 

 

 

 

 

 

 

DESCRIPTION 

The Expert nano model 200NANO1LT is an electronic regulator 

operating  with  microprocessor  designed  to  control  static 

refrigeration  units  operating  at  normal  temperature  with  off-

cycle  defrosting  (to  stop  compressor).  It  is  fitted  with  one 

analogue  input  for  NTC  or  PTC  temperature  probes  and  one 

relay  for  the  control  of  the  compressor.  The  regulator  can  be 

also configured for heat or alarm applications. 

 

PRINCIPAL CHARACTERISTICS 

 

Can be configured for hot or cold or alarm applications. 

 

Off-cycle  defrosting  can  be  set  on  the  basis  of  frequency  or 

duration. 

 

Key operated manual START/STOP defrosting. 

 

Key operated ON/OFF. 

 

Display/adjustment of temperature with decimal point. 

 

Flat front surface for easy cleaning and keys of ample dimensions 

which can be customised with various colours (on request). 

 

3-Digit LED display with sign, decimal point and system status icon.  

 

PEGO programming philosophy guaranteeing immediate start-up. 

 

IP65 front protection. Two-fold fastening option: clips / screws. 

 

Relay capacity and power depending on model. 

FRONT VIEW OF DEVICE 

 

 

 

COMBINED ACTIVATION OF KEYS AND THEIR FUNCTIONS 

FUNCTION / KEY COMBINATION 

SETTINGS PROGRAMMING   /

  (Set + 

 o 

)

 

Press  the  SET  key  to  view  the  current  SETPOINT  value 

(temperature). 
Keeping the SET key down and pressing either the (

) or (

key, the SETPOINT value can be changed. 

Release the SET key to return to view the room temperature; 

the changes made will be automatically saved. 

LEVEL 1 PROGRAMMING /

  (

 + 

)

 

Press the UP and DOWN keys simultaneously for over 3 sec. to 

access the Level 1 programming menu. The system leaves the 

menu after 30 seconds. 

LEVEL 2 PROGRAMMING

/ (

 + 

 + Stand-by)

 

Press  the  UP,  DOWN  and  STAND-BY  keys  simultaneously  for 

over 3 sec. to access the Level 1 programming menu. When the 

menu is accessed the system is placed in Stand-By mode. 

EXIT PROGRAMMING MENUS  /

  (

 + 

)

 

Pressing  the  UP  and  DOWN  buttons  simultaneously  in  any 

programming menu for over 3 sec. causes the system to save 

the settings entered and leave that menu. 
 

 

 

 

 

 
 

E N G L I S H

 

 

Power voltage 

 
Model 200NANO1LT01 

230 V

~

  +10/-15%  50/60Hz   

Model 200NANO1LT02 

Model 200NANO1LT11 

12V

~

 +10/-15%  50/60Hz 

12Vdc +10/-15%  class 2 

Absorbed power 

3 VA  Max 

Environment conditions 

 

Operating temperature 

-5T55°C  - humidity < 90% Rel. Hum. Not 

condensing 

Storage temperature 

-20T70°C - humidity < 90% Rel. Hum.  Not 

condensing 

Unsuitable operating 

environments 

Environments with strong vibrations or 

impacts; aggressive, polluted or corrosive 

atmospheres, exposure to direct solar 

radiation, explosive atmospheres or 

flammable gas. 

General characteristics 

 
Display 

3-Digit with sign, decimal point and 9 LED 

status indicators 

Resolution 

0,1 °C 

Probe precision (electronic)  ± 0,5 °C 
Reading range 

-45T99 °C 

Model 200NANO1LT01 

Model 200NANO1LT11 

Fixed screw clamps with cross-section from 

0.2 to  2.5mm

2

 

Model 200NANO1LT02 

Removable, screw clamps for cables with 

c/section 0.2 to  2.5mm

2

 

Software class: A  /  Parameters saved on non-volatile memory 

(EEPROM) 
Input characteristics 

 

Analogue inputs 

1 Input for NTC probe(10K Ώ 1%  at 25°C) 

Or 

1 Input for PTC probe(KTY83-121)     

Output characteristics Compressor relay (DO1) 

 
Model 200NANO1LT01 

Model 200NANO1LT11 

Model 200NANO1LT02 

N.O.  16(6)A  / 250V

~

 

Dimensional, insulation and mechanical characteristics 

 
Dimensions 

93x37x65mm  Depth 59mm  

Drill hole template 

71x29mm (+0,2/-0,1mm) 

Front protection rating 

IP65 with front board installation 

Installation 

In front of board by means of rear fastening 

clips or or two front screws 

Casing 

Plastic PC+ABS UL94 V-0 body, PC 

transparent front, Key panel PC or PC+ABS 

Insulation type 

Class II 

Conformity with EU low voltage directives, electromagnetic compatibility 

and EC mark 
Conforms to following EU Directives :  

Directives 2014/30/UE , 2014/35/UE 

Conforms to following harmonised standards:   

EN60730-1:2016, EN60730-2-9:2010, EN61000-6-1:2007,  EN61000-6-3:2007 

 

DRILL HOLE TEMPLATE (mm)

 

TECHNICAL DATA

 

KEY FUNCTIONS 

Key 

FUNCTION 

 

UP KEY 

Increases  values  /  Scrolls  parameters  in  ascending 

order. Acknowledges an alarm. 

 

DOWN KEY 

Decreases  values  /  Scrolls  parameters  in  descending 

order. 

If  pressed  for  over  3  seconds  activates  manual 

defrosting.  

Terminates  defrosting  if  pressed  for  over  3  seconds 

during the defrosting process. 

Stand 

by

 

STAND-BY KEY 

If pressed for over 1 seconds alternates the Stand-By 

with normal mode and vice versa. In Stand-By mode 

the system stops and the display signals OFF and the 

temperature alternating. 

 

SET KEY

 

Displays the set point. 

Allows  the  set  point  to  be  entered  when  pressed  in 

combination with the DOWN or UP keys. 

 

STATUS ICON 

ICON 

MEANING 

 

COLD FUNCTION ICON 

(icon activated with mOd=0/2)   

Led OFF = Cold function OFF 

Led ON =  Cold function ON 

Flashing Led = Cold function ON  waiting for C1 delay 

 

HOT FUNCTION ICON 

 (icon activated with mOd=1/3)   

Led OFF = Hot function OFF 

Led ON =  Hot function ON   

 

DEFROSTING ICON  

(icon activated with mOd=0/2)   

Led OFF = Defrosting OFF 

Led ON =  Defrosting ON   

 

ALARM ICON

 

Led OFF = No alarm present 

Led  ON  =  Indicates  temperature  alarm  intervention 

with remedy (HACCP alarm). 

Flashing Led =  Alarm present 

 
 

FASTENING TO PANEL BY MEANS OF TWO BACK CLIPS

 

FASTENING TO PANEL BY MEANS OF TWO FRONT SCREW

 

Screw 2,9x9,5mm

 

Screw 2,9x9,5mm

 

DIMENSIONS (mm)

 

Distance between hole centres: 77mm

 