The instructions are displayed as shown below.
】
3.
After the operating test is completed, press FUNCTION
key to return to the sewing display.
CAUTION
CAUTION
When any error message comes out, check the connection
of cords/air lines and the pressure of the filter regulator, and then
perform the test again. If the error is still shown, contact your local
Pegasus' sales office or representative.
FUNCTION
FUNCTION
機能選択
機能選択
PROGRAM
PROGRAM
プログラム
プログラム
1
. SWITCH TEST
→
2
. AI SENSOR TEST (Move the differential feed lever with INC.
▲
and DEC.
▼
keys.
→
Press
FUNCTION key
.)
→
3
. SENSOR TEST
→
4
. CLOTH SENSOR TEST
→
5
. CUTTER TEST (Press
CUTTER key
.)
→
6
. MOTOR STOP TEST (Press STOP key
while pressing the machine treadle.)
Testing mode
FUNCTION
FUNCTION
機能選択
機能選択
ON
Testing mode
If truoble occurs while the AI device is used, find the cause
performing the test mode.
1.
Turn on the power while pressing PROGRAMMING
and FUNCTION
keys
simultaneously.
The operation test display comes out.
CAUTION
CAUTION
Do not turn off the power until the operation test
display is shown. Otherwise memory may change.
2.
Proceed according to the instructions.