To access Service Menus, simultaneously press lower left and lower right keys. Changed values are automatically retained. Service Menu availability is dependent upon system type and
upon system configuration. Note: The Remote Indoor Zone Sensor must be enabled in the Service Menus (see Service Menu 170).
menU
FeatUre
oPtIons
stD.moDel
DeFaUlt
DescrIPtIon / comments
100*
Schedule Format
0-3
1
Select the schedule format on the Performance PRO T4000 Series.
0 = nonprogrammable
1 = programmable
2 = 5-1-1 schedule
3 = 5-2 schedule
101
Daylight-Saving
Time
0,1
0
Select daylight-saving time as it follows standard format in U.S.: It begins second Sunday of March at
2:00 AM and ends on the first Sunday of November at 2:00 AM.
0 = Disabled
1 = Enabled (2007 US Format)
110
System Type
1-11
1
Select the appropriate system configuration (determines available Service Menus).
1 = 1 Heat/1 Cool conventional
2 = 1 Heat/1 Cool heat pump
3 = Heat only without fan (2-wire systems)
4 = Heat only with fan
5 = Cool only
6 = 2 Heat/1 Cool heat pump (with auxiliary heat) and Emergency (Em) heat
7 = 2 Heat/2 Cool multistage conventional
8 = 2 Heat/ 1 Cool multistage conventional
9 = 1 Heat/ 2 Cool multistage conventional
10 = 2 Heat/ 2 Cool heat pump (no aux. heat)
11= 3 Heat/ 2 Cool heat pump (with auxiliary heat) and Emergency (Em) heat
120
Fan Control
(heating)
0,1
0
0 = Fossil Fuel: Gas/Oil/Propane heat (equipment controls heating fan)
1 = Electric Furnace (thermostat controls heating fan)
130
Changeover valve
(B/O terminal)
0,1
0
0 = B/O terminal controls valve in cooling
1 = B/O terminal controls valve in heating
140
Auxiliary Heat
0,1
0
0 = Electric backup heat
1 = Fossil fuel backup heat
150
Backlight
0,1
0
0 = Backlight temporarily on
1 = Backlight always on (low intensity, 24V only)
170
Remote Sensor
0-1
0
Select sensor if used (connected to the S1 Terminal). Contact PECO for more information on the Indoor
Remote Zone Sensor.
0 = No Sensor
1 = Indoor Sensor
230
Furnace Filter
Change Reminder
0; 30; 60; 90;
120; 365
0
Set a filter reminder timer; appears on digital display when timer expires (if programmed).
0 = Off
10 days; 30 days; 60 days; 90 days; 120 days; 365 days
240
Number of Program
Periods
2; 4 events
4
2 = 2 events per day
4 = 4 events per day
250
Clock format
12 or 24 Hours
12
12 = 12-hour clock mode
24 = 24-hour clock mode
260
Temperature Format
(°F or °C)
0,1
1
0 = Celsius
1 = Fahrenheit
270
Fan Off Delay Heat
0-99 Seconds
0
Select the amount of time (in seconds) that the fan will run after the thermostat heat outputs are turned
off.
280
Fan Off Delay Cool
0-99 Seconds
0
Select the amount of time (in seconds) that the fan will run after the thermostat cool outputs are turned
off.
290
Range Low
50-90 °F or
10-32°C
50°F (10°C)
Choose the lowest selectable temperature setpoint value.
300
Range High
50-90 °F or
10-32°C
90°F (32°C)
Choose the highest selectable temperature setpoint value.
310
Setback Low
Off; 50-82°F or
11-27°C
55°F (13°C)
Select the heat setpoint for setback mode.
0 = Off
50-82°F (11-27°C)
320
Setback High
Off; 58-90°F or
11-32°C
90°F (32°C)
Select the cool setpoint for setback mode.
0 = Off
58-90°F (11-32°C)
330
Zone Temp Offset
+/-9°F or +/-
4.5°C
0°F (18 °C)
Adjusts the displayed value; may differ from actual zone temperature.
taBle 2. aDvanceD conFIGUratIon: servIce menUs