26
5 . 5 . C o n f i g u r i n g t h e P a g e M a t r i x C o n t r o l l e r
As mentioned previously, the PageMatrix controller supports up to sixteen paging stations
simultaneously. In larger applications where multiple controllers are necessary, the various
PageMatrix units must be configured for IDs beyond the default 1-16 setting. This is accomplished
by changing the DIP switch settings inside the unit.
1. Remove top plate of the controller (six screws).
2. Now viewing the inside of the unit, find the DIP switch (labeled SW100) located at the front left
side of the unit.
3. You will only adjust switches 1 and 2 according to the chart below.
4. Switches 3 through 8 are inactive.
Stations 1 - 16
Stations 33 - 48
Stations 49 - 64
DIP SETTINGS
CONTROLLER IDs
Stations 17 - 32
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
1 2 3 4 5 6 7 8
O
N
NOTE:
Factory settings default to 1-16
Summary of Contents for PageMatrix
Page 1: ...ARCHITECTURAL ACOUSTICS O W N E R S M A N U A L PAG E MAT R I X Controller...
Page 25: ...5 4 5 Pin Wiring Diagram 25 Mic Switch GND Audio Audio...
Page 48: ...5 4 5 P i n M i c W i r i n g D i a g r a m Mic Switch GND Audio Audio 48...
Page 72: ...Mic Switch GND Audio Audio 5 4 5 Pin Wiring Diagram 72...
Page 96: ...Mic Switch GND Audio Audio 5 4 5 Pin Wiring Diagram 96...
Page 100: ...100 NOTES...
Page 101: ...101 NOTES...