30
Current Consumption
(Multiply current by 0.5 for 230 V units)
Rated power
15.4 A (4 Ohms)
13.2 A
9.9 A (8 Ohms)
1/3 power
9.9 A (4 Ohms)
8.6 A
6.3 A (8 Ohms)
1/8 power
6.6 A (4 Ohms)
5.8 A
4.2 A (8 Ohms)
Idle
0.4 A
0.7 A
Thermal Emission
1/3 power
3147 BTU/hr (4 Ohms)
2614 BTU/hr
1990 BTU/hr (8 Ohms)
1/8 power
2364 BTU/hr (4 Ohms)
2036 BTU/hr
1500 BTU/hr (8 Ohms)
Controls
Front: 4 channel input signal attenuators‚ AC switch
Rear: 2 x 4 DIP switches for input module assign‚ 2 output mode switches
Indicator LEDs
4 clip‚ 4 signal‚ 1 power
Protection
Over-temperature‚ DC‚ turn on/off transients‚ subsonic‚ incorrect load‚ short-circuit
Connectors
Input: Four 3-position Euro-style detachable terminal blocks‚ two ports for MMA
™
input modules
Output: Two 4-position barrier strips
Construction
16-gauge steel-reinforced with 12-gauge rack ears
Dimensions
Height: 3.50" (8.84 cm); 2 EIA rack spaces
Width‚ front: 19.00" (48.26 cm)
Width‚ rear: 17.00" (43.18 cm)
Overall depth: 17.05" (43.31 cm)
Mounting depth: 16.63" (42.24 cm) behind front rack ears
W
We
eiig
gh
htt
40 lbs. (18.1 kg)
P
Po
ow
we
err R
Re
eq
qu
uiirre
em
me
en
nttss
100‚ 120‚ 230–240 Vac‚ 50–60 Hz
T
Te
esstt C
Co
on
nd
diittiio
on
nss
120Vac‚ 60 Hz line input voltage maintained
All channels operating unless otherwise noted
(Due to our efforts for constant improvements‚ features and specifications listed herein are subject to change without notice.)
Summary of Contents for Architectural Acoustics ICS 4200
Page 1: ...ICS 4200 4 Channel Power Amplifier User Manual...
Page 13: ...13 Example of a 70 Volt constant voltage distribution system...
Page 27: ...27 Example of a 70 Volt constant voltage distribution system...
Page 40: ...40 Example of a 70 Volt constant voltage distribution system...
Page 51: ...51 Example of a 70 Volt constant voltage distribution system...
Page 53: ...53 N NO OT TE ES S...
Page 54: ...54 N NO OT TE ES S...