3.4. AC Current
Range
Resolution
Accuracy
2 mA
1 µA
+/- 1,2% rdg. + 3 dgt.
200 mA
100 µA
+/- 2,0% rdg. + 3 dgt.
20 A
10 mA
+/- 3,0% rdg. + 10 dgt.
Overload protection
0,2 A / 250 V fuse in mA-Input (Fast-blow fuse)
20 A / 250 V fuse in 20 A-Input (Fast-blow fuse)
20 A for max. 30 sec.
Frequency - range: 50 ... 100 Hz
3.5. Resistance
Range
Resolution
Accuracy
200
0,1
+/- 1,0% rdg. + 4 dgt.
2 k
1
+/- 1,0% rdg. + 2 dgt.
20 k
10
+/- 1,2% rdg. + 2 dgt.
200 k
100
2 M
1 k
20 M
10 k
+/- 2,0% rdg. + 5 dgt.
Overload protection: 250 V DC/ACrms
3.6. Frequency
Range
Resolution
Accuracy
20 kHz
10 mHz
+/- 1,5% rdg. + 5 dgt.
Input voltage: 250 V DC/ACrms
Sensitivity: 0,2 Vrms... 10 Vrms