background image

Page 5

Warranties and Liabilities

1.  The Company warrants that it has title to the Goods.
2.  Subject to the provisions of this clause the Company warrants that the Goods  

 

shall comply in all material respects with any specification referred to in the Order  
Confirmation (as the same may be amended) and shall, subject thereto, be free    

from defects in material and workmanship for the lesser of a period of twelve  

 

months from the date of delivery or thirteen months from the date of dispatch    

from the factory.

3.  Save as provided in this clause and except where the Goods are sold to a person   

dealing as a consumer (within the meaning of the Unfair Contract Terms Act  

 

1977) all warranties, conditions or other terms implied by statute or common  
law are hereby expressly excluded save to the extent they may not be lawfully 
excluded. When the Goods are sold to a consumer within the meaning of the Unfair 
Contract Terms Act 1977 their statutory rights are not affected by the provisions of 
this clause.

4.  In the event of the Customer making a claim in respect of any defect in terms of    

clause 2 hereof the Customer must. 
1.  Reasonably satisfy the Company that the Goods have been properly installed, 
commissioned, stored, serviced and used and without prejudice to the generality 
of the foregoing that any defect is not the direct or indirect result of lack of repair 

and/or servicing, incorrect repair and/or servicing, use of wrong materials and/or 

incorrect spare parts 
2.  Allow the company to inspect the Goods and/or any installation and any relevant 

packaging as and when reasonably required by the Company.

5.  Subject to the Company being notified of any defect as is referred to in sub- 

 

clause 2 hereof within a reasonable time of it becoming apparent and subject always 

to the terms of sub-clause 4 hereof, the Company shall, in its option, replace or 
repair the defective Goods or refund a proportionate part of the Price. The Company 

shall have no further liability to the Customer (save as mentioned in sub-clause 6 
hereof).

6.  The Company shall be liable to indemnify the Customer in respect of any claim 

for death or personal injury to any person in so far as such is attributable to the 
negligence or breach of duty of the Company or any failure by the Company to 
comply with the provisions of sub-clause 2 hereof.

7.  Save as provided in sub-clause 2 hereof the Company shall not be liable in respect 

of any claim by the Customer for costs, damages, loss or expenses (whether direct, 
indirect, consequential or otherwise) or indemnity in any respect howsoever arising 

including, but not by way of limitation, liability arising in negligence (other than 

pursuant to clause 6 above) that may be suffered by the Customer or any third 
party.

Summary of Contents for Precision Nitrogen 250cc

Page 1: ...Precision Nitrogen User Manual Rev 4 RSID 226 EN 21 12 17 Precision Nitrogen All Models User Manual...

Page 2: ...tallation 13 Generator Environment 13 Generator Overview 14 Nitrogen General Dimensions 14 Nitrogen Trace General Dimensions 15 Nitrogen Rear Connections 16 Nitrogen Trace Rear Connections 17 Electric...

Page 3: ...ntended for end users and has been written as a reference document where you can skip to the relevant information Users can refer to the contents page to find the relevant information Please review ea...

Page 4: ...ons the Precision Nitrogen Trace model can be used for carrier gas in GC applications as it also removes hydrocarbons by means of catalytic oxidation Other features include Generates Nitrogen on deman...

Page 5: ...ality of the foregoing that any defect is not the direct or indirect result of lack of repair and or servicing incorrect repair and or servicing use of wrong materials and or incorrect spare parts 2 A...

Page 6: ...ully understood or met A CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the genera...

Page 7: ...ds and other normative requirements Low Voltage Directive 2006 95 EC EN 61010 1 2010 Electrical Equipment for measurement control and laboratory use Electromagnetic Compatibility Directive 2004 108 EC...

Page 8: ...ronic Equipment Directive 2012 19 EU These obligations are being met within the B2B compliance group Peak Scientific Instruments Ltd has developed all reasonable due diligence controls to ensure that...

Page 9: ...erator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outlet Flow Rate 250cc 600cc 1000cc Start up time 1 5 Hours Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 1 x BS...

Page 10: ...5 Hours Particles 0 01 m Phthalates NONE Suspended Liquids NONE Gas Outlets 1 x BSPP For optimum performance from your Precision Nitrogen generator the inlet gas supply pressure should be 30PSI greate...

Page 11: ...Air Inlet Quality ISO 8573 1 2010 Class 1 4 1 Particles 0 01 m Generator Outlets Maximum Gas Output Pressure 5 5 bar 80 psi Maximum Outlet Flow Rate 250cc 600cc 1000cc Start up time 1 5 Hours Particle...

Page 12: ...r the Peak Partner from where the unit was purchased Follow the unpacking instructions posted on the side of the crate It will require two people to remove the unit from the shipping crate and to mano...

Page 13: ...t ports are located on the output panel at the rear of the unit Unpacking Instructions The unit weight constitutes a two person lift and as such safe lifting practices should be employed do not attemp...

Page 14: ...s affected by ambient conditions Note should also be taken to the proximity of Air Conditioning outlets These can sometimes give rise to pockets of air with high relative humidity Operation of the uni...

Page 15: ...15 Generator Overview Nitrogen General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator 380 mm 14 9 540 mm 21 2 256...

Page 16: ...Page 16 Nitrogen Trace General Dimensions The generator must always be placed on a flat level surface Failure to do so will affect the performance of the generator 380 mm 14 9 540 mm 21 2 406mm 15 9...

Page 17: ...Page 17 Nitrogen Headspace Rear Connections Power Inlet Compression Fitting 1 8 Compression Fitting Mains Cable...

Page 18: ...Page 18 Nitrogen Trace Rear Connections Power Inlet Compression Fitting 1 8 Compression Fitting Mains Cable...

Page 19: ...nnecting the unit to the mains supply please check the information on the serial plate The mains supply must be of the stated AC voltage and frequency EARTH GROUND E Green Yellow or Green LIVE L Brown...

Page 20: ...ate count should not exceed 20 000 particles in the 0 1 0 5 micron size range 400 particles in the 0 5 1 micron range and 10 particles in the 1 5 micron size range Class 4 Water A pressure dew point P...

Page 21: ...to the application On Demand Gas The generator will produce nitrogen on demand If the application is operating and requires a gas flow the system it is connected to will supply this to suit the requir...

Page 22: ...s supply between the generator and the application can lead to a reduction in efficiency Tubing Lengths The diameter of the tubing which will be connected to the gas outlet is important and is determi...

Page 23: ...nly As an alternative to purchasing the 12 month service items individually an Annual Service Kit is available as one part number This contains all the filters required for this unit and offers a cost...

Page 24: ...twork of certified Peak engineers stationed throughout the globe Peak s rapid response team are never far away and our commitment is to keep your generator running day in day out protecting your labor...

Page 25: ...from the cloth prior to use Cleaning should only be undertaken with the power switched off and the power cord removed from the rear of the generator Under no circumstances should any solvents or abra...

Page 26: ...s turned on Check the fuse in the power cord plug Contact your service provider The fascia LED s have not illuminated but the power switch is illuminated Contact your service provider The instrument i...

Page 27: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Page 28: ...ndustry leading rapid response service to our customers With Peak Protected your laboratory s productivity becomes our top priority To discuss Peak Protected generator cover and payment options speak...

Reviews: