background image

 

 

 

 

MODEL:

 

RF-

HEMiS™ Clone 

Manager 

Document Number:

 

PD196-391R3 

 

User Manual 

Page 6 of 13 

 

 

PDi Communication Systems, Inc. 

 40 Greenwood Ln 

 Springboro, Ohio 45066 USA 

 

www.pdiarm.com

 an

www.mymedTV.com

 

 Phone 800.628.9870 

 

 

INITIAL RF CLONE MANAGER APP CONFIGURATION  

To prepare the RF Clone Manager app for use, some initial configuration is required. 

1.

 

Turn on the RF-HEMiS by pressing the red power button on the front right of the machine. 

2.

 

Once the system is fully booted and logged in, start the RF Clone Manager app by double-clicking the PDi 
icon on the desktop. 

3.

 

From the Main Screen, click the “Broadcast Settings” tab at the top left.

 

4.

 

The Broadcast Settings Menu should appear (see “Broadcast Settings Menu” f

or details). 

5.

 

Change the “Channel Type” and “Channel Number” setting to the channel your facility has chosen for 

broadcasting updates (see TV user manual for details). 

6.

 

Set the Signal Level (in dBmV) of the RF output to match other QAM channels entering your RF combiner. 

7.

 

If necessary, switch from QAM to VSB modulation. 

8.

 

Click “Save Settings,” and the app is ready for use.

 

 
USING THE RF CLONE MANAGER APP 

 

Overview  

The RF Clone Manager Application allows a user to manage and broadcast Television Data Files (TDFs) and splash 
images to connected televisions. TDFs can contain TV settings or firmware updates.  To use the application, a user 

must have all the necessary TDFs for each TV being updated.  Then the user creates one or more Updates via the 

“Add Update”

 button, selects them from the Update List by clicking the checkbox next to their name, and finally 

clicks the Broadcast button. 
 

Loading Television Data Files (TDFs) 

To make use of the RF Clone Manager app, at least one TDF is required. Settings TDFs are generated by television 

sets and saved to a USB flash drive (see your TV user manual for details). 

(Firmware TDF’s are provided by PDi).  

Once the requisite TDFs are saved to a flash drive, the drive must be connected to the RF-HEMiS and TDF files 

transferred to the RF-

HEMiS. For convenience, there is a “TDFs” folder on the desktop for the files, but any location 

on the device will work. 

 

Assigning Television Groups 

PDi televisions have the option to be assigned to a specific “Group,” which allows them to r

eceive targeted update 

broadcasts. Using this option, televisions in different areas of the facility can be assigned specific groups which, in 
turn, will receive specific settings configurations (channel lineups, language settings, etc). This allows complete 

control over the content that certain groups have available.   
 

By default, all televisions belong to the “Default” update group and will only receive updates targeting that group. 

However, each TV’s group can be changed to one of 30 different options. 

Once changed, TVs will only receive 

updates that target their new group.  

 

Additionally, in the app’s “Edit Groups” menu, custom tags can be applied to the group labels for more convenient 

and intuitive organization within the app (see “

Edit Groups menu

” f

or details). 

 

Adding a Splash Image 

PDi televisions have the option to show a custom image each time they are turned on. When a new image is 
broadcast, TVs will replace the current splash image with the new one.  PDi Televisions do not scale (shrink, zoom 

Summary of Contents for RF-HEMiS PD890-1009

Page 1: ...mymedTV com USER MANUAL Document Number PD196 391R3 RF HEMiS Head end Management Integrated TV Server PD890 1009...

Page 2: ...TV Firmware 4 Enabling RF Updating 4 RF HEMiS INSTALLATION 4 SECURITY 5 REMOTE ADMINISTRATION 5 MAINTENANCE 5 INITIAL RF CLONE MANAGER APP CONFIGURATION 6 USING THE RF CLONE MANAGER APP 6 Overview 6 L...

Page 3: ...the head end It does this by inserting upgrade information into the building s RF coax cable plant Compatible TVs include PDi A series E series medTV and medTAB products Each model TV may be updated i...

Page 4: ...ng the patient of what is happening The update may take up to 4 minutes TV s with automatic updating disabled will not search for updates They may be manually updated by entering the setup menu and na...

Page 5: ...s available on all five ethernet ports not just the dedicated IPMI port IPMI allows for remote administration even when the RF HEMiS is powered down IPMI is shipped in the enabled state When it detect...

Page 6: ...clicking the checkbox next to their name and finally clicks the Broadcast button Loading Television Data Files TDFs To make use of the RF Clone Manager app at least one TDF is required Settings TDFs a...

Page 7: ...appear 3 Enter a meaningful update name into the Update Name field 4 Select the group that you are targeting from the Update Group dropdown menu 5 Click the Add TDF button to select and add a TDF file...

Page 8: ...pringboro Ohio 45066 USA www pdiarm com and www mymedTV com Phone 800 628 9870 RF CLONE MANAGER APP REFERENCE Main Screen The Main Screen of the RF Clone Manager app allows access to all other parts o...

Page 9: ...tton will begin the broadcast Clicking it while the broadcast is running will stop it 4 Broadcast Activity Indicator Indicates when updates are being broadcast 5 Saved Updates List All of the updates...

Page 10: ...in pixels The sizes are typically either 1920x1080 or 1366x768 See the TV User Manual for exact specification 5 File Clear Buttons Removes the specified file from the update 6 Cancel Button Ends the...

Page 11: ...modulation for the broadcast Default QAM 5 Broadcast Device Selector Allows the user to select between available broadcast adapters The RF HEMiS typically only has one broadcast device present 6 Save...

Page 12: ...defaults their Group IDs 5 Save Groups Button Save your custom label to memory SUPPORT INFORMATION PDi Communication Systems Inc Springboro OH www pdiarm com 800 628 9870 LIMITED WARRANTY PDi Communic...

Page 13: ...r of TV s updating simultaneously Unlimited Intuitive Graphical user interface YES Remote administration IPMI and Windows RDP TV Compatibility Minimum Firmware Version AxxA AxxB V1 16 ExxLEDA ExxLEDB...

Reviews: