Better Solutions Are Within Reach
®
MODEL NUMBER:
PDI-772HE-IND
Document Number:
PD196-181R3
Individual Input Port Central Power Supply
Page 8 of 12
PDi Communication Systems, Inc. 40 Greenwood Lane Springboro, Ohio 45066 USA PH 1-800-628-9870 FX 937-743-5664
Cabling the Supply For Individual Signals - Continued
This supply is provided with conduit knockouts on the top, left side, and bottom of the cabinet as cable entry
points.
1.
Verify the power supply is disconnected
from AC power
2.
Loosen (2) screws from the face of the
cabinet and detach the ventilation cover
exposing the RF “F” connector rows.
3.
Connect the RF signal cable from the
satellite or set top box to the
RF IN “F”
connector (Top Row).
Note: Be sure the
center conductor is straight.
4.
Connect the coax cable to the arm mounted
TV to the corresponding RF OUT “F”
connector (Bottom Row). The PDI-772HE-
IND supports up to 10 satellite or set top
boxes.
Note: Be sure not to cross thread
the RF cable on the F-conn of the 772HE-
IND.
CAUTION: Connecting the set top box signal cable to RF OUT (Bottom Row) will result in damage
to the box.
5.
Replace the ventilation cover.
Tighten the (2) cover screws.
6.
Use a permanent marker to identify
each cable on the LOCATION label
next to the circuit breaker field.