USER GUIDE
5
PCS 4000
SINGLE WELL CONTROLLER
Controller reports
Plunger Travel Time History =
☛
READ 06
This report provides information about the 25 most recent
plunger travel times. The first display shows the number
of times the plunger surfaced and the average travel time.
Example:
GOOD RUNS: 25
AVE: 0:08:22
Use the READ button to scan through the report.
The next 25 displays show the 25 most recent plunger
travel times.
This example shows the most recent plunger run. The
plunger surfaced after 8 minutes and 15 seconds of
OPEN TIME.
LAST PLUNGER- 0
A 0:08:15
This example shows the 2nd most recent plunger run.
LAST PLUNGER- 1
A 0:08:15
This example shows the 25nd most recent plunger run.
LAST PLUNGER-24
A 0:08:15
This example shows the most recent plunger run. The
plunger surfaced after 10 minutes and 40 seconds of
OPEN TIME and B OPEN TIME.
LAST PLUNGER- 0
B 0:10:40
This example shows the most recent plunger run. The
CASING DROP PRESSURE was reached before the
plunger arrived.
LAST PLUNGER- 0
C 0:09:26
This example shows the most recent plunger run. The
plunger did not surface.
LAST PLUNGER- 0
NO PLUNGER
To exit the report at any display, press CE.
Valve/Plunger Counts History, Total Time Reports, and
Plunger Travel Time History =
☛
READ 10
This reporting option displays the 2 Valve and Plunger
Counts Histories (READ 04 and READ B4), the 2 Total
Time Reports (READ 07 and READ B7), and the Plunger
Travel Time History (READ 06). To display the next report,
press READ.
A-Valve and Plunger Counts History =
☛
READ 04
This report shows how many times the A-valve opened,
and how many times the plunger arrived while the A-valve
was open.
Example:
A PLUNGER= 92
A VALVE = 96
In the example:
A VALVE = 96 shows that the A-valve opened 96 times.
A PLUNGER= 92 shows that the plunger arrived 92
times while the A-valve was open.
96–92=4. The plunger did not arrive 4 times while the
A-valve was open.
Note:
If the well has a B-valve, this report shows 2 A-valve
counts for each B-valve count in the B-Valve and Plunger
Counts History. If the plunger did not arrive 4 times while
the A-valve was open, the plunger may have arrived up to
2 times while the B-valve was open.
B-Valve and Plunger Counts History =
☛
READ B4
This report shows how many times the B-valve opened,
and how many times the plunger arrived while the B-valve
was open.
Example:
B PLUNGER= 2
B VALVE = 2
In the example:
B VALVE = 2 shows that the B-valve opened 2 times.
B PLUNGER= 2 shows that the plunger arrived 2 times
while the B-valve was open.
A-Valve Total Time Report =
☛
READ 07
This report shows 2 times of up to 999 hrs., 59 min., 59
sec. accumulated since the report was last cleared:
Total OPEN TIME and DELAY TIME (SALES).
Total time that the controller was closed. MANDATORY
SHUT-IN (if any), FALL TIME (if any), and CLOSE TIME
are accumulated under TOT CLS time.
Example:
A TOTAL 16:31:13
TOT CLS 8:12:45
B-Valve Total Time Report =
☛
READ B7
This report shows 2 times of up to 999 hrs., 59 min., 59
sec. accumulated since the report was last cleared:
Total B OPEN TIME.
Total time that the controller was closed. MANDATORY
SHUT-IN (if any), FALL TIME (if any), and CLOSE TIME
are accumulated under TOT CLS time.
Example:
B TOTAL 1:24:32
TOT CLS 8:12:45