- PCME QAL 181 MANUAL: 9 -
Air Purge requirements
Requires continuous air supply of 50 litres/minute.
Provided either by a blower (PCME supplied) or instrument air.
With instrument air, filtration is require (the use of PCME
supplied air filtration kit is strongly recommended).
Sensor Options
Sensor Type options
Standard sensor
High temperature sensor
0-250°C
0-500°C
Insertion length
The insertion length can be adjusted from 15mm to 600mm
by adjusting the flange position.
ATEX/ IECEx Category options
ATEX : Category 3 gas (Zone 02) , Category 2 dust (Zone 21)
IECEx : Category 3 gas (Zone 02) , Category 2 dust (Zone 21)
Sensor Accessories
Air Filtration Kit
See section in manual
Low Pressure Blower
Dimensions: 300 x 300 x 180 mm
Rating: 100-240V 1.3A 50-60Hz
Control Unit Specification
Standard System
PLUS System
Controller type
Interface Module
MultiController
No of sensor
channels
1
1 -16