In part 3 of ISO 10816, revised in 2009, the zone borders are specified for vibration severity of machines with a power of 15 kW to 50 MW (Table
2).
Table 2: Vibration Severity classification in accordance with ISO 10816-3
Part 7 of the ISO 10816 deals specifically with rotodynamic pumps (Table 3).
E
ng
lis
h
Table 3: Classification of the vibration severity of rotodynamic pumps in accordance with ISO 10816-7