Figure 27: K(t) mode with newly detected VMID
If the VMID point ID has been saved but not the K(t) start values, then this is the next step. By pressing the ▼ key the currently measured RMS RMS(t) and peak value
Peak(t) are saved as K(t) the start value RMS(0) and Peak(0) (Figure 28).
Figure 28: Saving K(t) start values
When the sensor is newly placed on the VMID measuring point, the instrument automatically switches to the K(t) display. It then reads the start values from the memory
and calculates the K(t) value from the currently measured RMS(t) and Peak(t) values (Figure 29).
Press the ▼ key to save the K(t) values. Press F1 to view the graphic trend display. (cf. Section 7.5)
Note: If the instrument displays OVERLOAD, it is not necessarily the result of a too high acceleration value. It can also be due to a base value of zero, which causes a
division through zero.